INPUT / OUTPUT
Digital Outputs
145
146
147
148
149
150
151
152
[Digital Out1 Sel]
[Digital Out2 Sel]
[Digital Out3 Sel]
[Digital Out4 Sel]
[Digital Out5 Sel]*
[Digital Out6 Sel]*
[Digital Out7 Sel]*
[Digital Out8 Sel]*
Selects the source of the value that drives the digital output. See Option
Definitions for [Digital Outx Sel], [Relay Out 1 Sel] and [Relay Out 2 Sel] on
page 200
.
*These parameters are used to configure the digital outputs on the I/O
Expansion circuit board.
Notes: Option 16 “Encoder Err” was changed for firmware version v5.002.
Option 30 “Brake Slip” was added for firmware version 6.001.
Options:
Default:
Default:
Default:
Default:
Default:
Default:
Default:
Default:
5 =
9 =
2 =
4 =
26 =
0 =
0 =
0 =
“Ready”
“Fault”
“Spd Thresh”
“CurrentLimit
“Ala rm
“Not Used”
“Not Used”
“Not Used”
16-bit
Int
File
Group
No.
Parameter Name & Description
See page 114 for symbol descriptions
Values
Data Type
Related
0 = “Not Used” (Off) 8 = “Spd Limited” 16 = “Spd Fdbk Err” 24 = Reserved”
1 = “Spd Zero Thr” 9 = “Fault” 17 = “Diam Calc” 25 = “Reserved”
2 = “Spd Thresh 10 = “Power Loss” 18 = “Input1 Cmp 26 = Alarm
3 = At Speed” 11 = “UserDefinedA 19 = “Diam Reached” 27 = “Running
4 = “CurrentLimit” 12 = “UserDefinedB” 20 = “Speed Match 28 = Jogging”
5 = “Ready” 13 = “Stop Control” 21 = Accelerating” 29 = Active”
6 = “Ramp Pos” 14 = “Field Loss” 22 = “Decelerating” 30 = Brake Slip
7 = “Ramp Neg 15 = “Spd Fbk Loss” 23 = “Brake Cmd”