Programming and Parameters Chapter 3
APPLICATIONS
Winder Functions
1210 [W Target]
Number of the parameter to which the winder speed reference is written.
Notes: Added options 0…47 for firmware version 4.001. Added option 48
“Reserved” for firmware version 5.002.
Default:
Min/Max:
0
0 / 65535
16-bit
Int
Options:
1212 [Acc Dec Filter]
Internal acceleration/deceleration calculation filter for the Torque Winder line
speed reference.
Default:
Min/Max:
Units:
30
0 / 5000
ms
16-bit
Int
1213 [Actual Comp]
Active compensation status (sums up the static, dynamic and inertial frictions) as a
percentage of the drive rated current.
Note: This parameter can be assigned to an analog output.
Default:
Min/Max:
Units:
Read Only
–/+200
%
16-bit
Int
1214 [Closed Loop En]
Enables/Disables closed loop tension control (used with a load cell).
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
16-bit
Int
1215 [Speed Demand En]
Enables/Disables the speed reference calculation for the Torque Winder
application.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“Enabled”
16-bit
Int
1216 [Spd Match Torque]
Sets the torque current during the launching and change phase.
Default:
Min/Max:
Units:
100
0 / 200
%
16-bit
Int
1217 [W Reference]
Angular speed reference.
Note: This parameter can be assigned to an analog output; 10V = 100% of Par 45
[Max Ref Speed].
Default:
Min/Max:
Units:
Read Only
–/+8192
rpm
16-bit
Int
1160
1255 [Jog TW Speed]
Torque Winder jog reference. The parameter is entered as a percentage of Par 1160
[Line Speed Pct].
Default:
Min/Max:
Units:
0
0 / 100
%
16-bit
Int
1160
1256 [Jog TW Enable]
Enables/Disables the Torque Winder jog function.
Note: This parameter can be assigned to a digital input.
Default:
Options:
0 =
0 =
1 =
“Disabled”
“Disabled”
“E
nabled”
1
6-bit
Int
File
Group
No.
Parameter Name & Description
See page 114 for symbol descriptions
Values
Data Type
Related
A
0 = “Not Used” 17 = “Max Fld Pct” (Par 467) 34 = “UsrDefined15” (Par 518)
1 = “Cur Lim Pos” (Par 8) 18 = “Reserved” 35 = “Load Comp” (Par 698)
2 = “Cur Lim Neg” (Par 9) 19 = “UsrDefined0” (Par 503) 36 = “Out Volt Lvl” (Par 921)
3 = “Reserved” 20 = “UsrDefined1” (Par 504) 37 = “Reserved”
4 = “Reserved” 21 = “UsrDefined2” (Par 505) 38 = “Speed Ratio” (Par 1017)
5 = “TrqRedCurLim” (Par 13) 22 = “UsrDefined3” (Par 506) 39 = “Reserved”
6 = “Torque Ref” (Par 39) 23 = “UsrDefined4” (Par 507) 40 = “Reserved”
7 = “Trim Torque” (Par 40) 24 = “UsrDefined5” (Par 508) 41 = “Tension Red” (Par 1179)
8 = “Reserved” 25 = “UsrDefined6” (Par 509) 42 = “Reserved”
9 = “Trim Ramp” (Par 42) 26 = “UsrDefined7” (Par 510) 43 = “Reserved”
10 = “Trim Speed” (Par 43) 27 = “UsrDefined8” (Par 511) 44 = “CloseLp Comp” (Par 1208)
11 = “Reserved” 28 = “UsrDefined9” (Par 512) 45 = “Reserved”
12 = “Reserved” 29 = “UsrDefined10” (Par 513) 46 = “Reserved”
13 = “Reserved” 30 = “UsrDefined11” (Par 514) 47 = “Reserved”
14 = “Adaptive Ref” (Par 183) 31 = “UsrDefined12” (Par 515) 48 = “Reserved”
15 = “Reserved” 32 = “UsrDefined13” (Par 516)
16 = “Reserved” 33 = “UsrDefined14” (Par 517)
A
A
A
A
A
A
A