Rockwell Automation Publication 20P-UM001K-EN-P - July 2014 153
Programming and Parameters Chapter 3
DYNAMIC CONTROL
Ramp Rates
660 [Accel Time 1]
Sets the rate of acceleration for linear ramp 1.
Acceleration rate for ramp 1 = Par 2 [Maximum Speed] / Par 660 [Accel Time 1].
Default:
Min/Max:
Units:
10
0 / 65535
s
16-bit
Int
2
662 [Decel Time 1]
Sets the rate of deceleration for linear ramp 1.
Deceleration rate for ramp 1 = Par 2 [Maximum Speed] / Par 662 [Decel Time 1].
Default:
Min/Max:
Units:
10
0 / 65535
s
16-bit
Int
2
665 [S Curve Accel 1]
Amount of time (approximately half at the start and half at the end) applied to the
S-curve during Accel 1 changes. When Par 19 [S Curve Time] is changed this
parameter is automatically set to the same value. For asymmetrical S-curve ramps,
set this parameter after [S Curve Time] is changed.
Note: See S-curve Configuration on page 315
for more information.
Default:
Min/Max:
Units:
1.00
0.10 / 15.00
s
Real 19
666 [S Curve Decel 1]
Amount of time (approximately half at the start and half at the end) applied to the
S-curve during Decel 1 changes. When Par 19 [S Curve Time] is changed this
parameter is automatically set to the same value. For asymmetrical S-curve ramps,
set this parameter after [S Curve Time] is changed.
Note: See S-curve Configuration on page 315
for more information.
Default:
Min/Max:
Units:
1.00
0.10 / 15.00
s
Real 19
667 [S Curve Accel 2]
Amount of time (approximately half at the start and half at the end) applied to the
S-curve during Accel 2 changes. When Par 19 [S Curve Time] is changed this
parameter is automatically set to the same value. For asymmetrical S-curve ramps,
set this parameter after [S Curve Time] is changed.
Note: See S-curve Configuration on page 315
for more information.
Default:
Min/Max:
Units:
1.00
0.10 / 15.00
s
Real 19
668 [S Curve Decel 2]
Amount of time (approximately half at the start and half at the end) applied to the
S-curve during Decel 2 changes. When Par 19 [S Curve Time] is changed this
parameter is automatically set to the same value. For asymmetrical S-curve ramps,
set this parameter after [S Curve Time] is changed.
Note: See S-curve Configuration on page 315
for more information.
Default:
Min/Max:
Units:
1.00
0.10 / 15.00
s
Real 19
1410 [Jog Ramp Time]
Sets the rate of acceleration and deceleration while the Jog function is active. The
Jog rate = Par 2 [Maximum Speed] / Par 1410 [Jog Ramp Time].
Note: This parameter was added for firmware version 2.001.
Default:
Min/Max:
Units:
10
0 / 65535
s
16-bit
Int
2
Load Limits
13 [Torq Red CurLim]
The armature current limit, defined as a percentage of the value defined in Par 179
[Nom Mtr Arm Amps] when Par 342 [Torque Reduction] is set to 1 “Active.
Default:
Min/Max:
Units:
100
0 / 200
%
16-bit
Int
342
696 [Droop Percent]
Droop function gain is a percentage of the ratio between Par 45 [Max Ref Speed]
and the difference of Par 698 [Load Comp] – Par 41 [Current Reg In]. Therefore,
when the difference between Par 698 [Load Comp] and Par 41 [Current Reg In] =
100% and Par 696 [Droop Percent] = 100%, the speed reference correction signal
is equal to Par 45 [Max Ref Speed].
Note: See Droop Compensation on page 285
for more information.
Default:
Min/Max:
Units:
0.00
0.00 / 100.00
%
Real 41,
45,
698
697 [Droop Filter]
Droop filter time constant for the Droop function.
Notes: See Droop Compensation on page 285 for more information. Changed the
default value from 0 to 100 for firmware version 6.001.
Default:
Min/Max:
Units:
100
0 / 1000
ms
16-bit
Int
698 [Load Comp]
The load compensation signal. This value is typically equal to the “master” drives
current. The load compensation signal is a percentage of I
dn
.
Default:
Min/Max:
Units:
0
+ / –200
%
16-bit
Int
File
Group
No.
Parameter Name & Description
See page 114 for symbol descriptions
Values
Data Type
Related
A
A
A
A
A
A
A
A