Manual
Installation Instructions
23P-IN004A-EN-P
PowerFlex DC Stand-Alone Regulator (SAR)
Field SCR Module and Dual Diode Module
What This Kit Includes
Rockwell Automation recommends that the field SCR module and dual diode
module be replaced at the same time.
• One field SCR module or one dual diode module
• Two mounting screws with captive lock washers
• Static strap
Tools That You Need
• Phillips
®
screwdriver
• Hexalobular screwdriver
• Isopropyl alcohol
• Thermal grease
Phillips
®
is a registered trademark of Phillips Screw Company.
ATTENTION: Only qualified personnel familiar with DC drives and
associated machinery should plan or implement the installation,
start-up, and subsequent maintenance of the system. Failure to comply
may result in personal injury and/or equipment damage.
ATTENTION: To avoid an electric shock hazard, ensure that all power to
the SAR has been removed before performing the following.
ATTENTION: This SAR contains ESD (Electrostatic Discharge) sensitive
parts and assemblies. Static control precautions are required when
installing, testing, servicing, or repairing this assembly. Component
damage may result if ESD control procedures are not followed. If you are
not familiar with static control procedures, reference A-B publication
8000-4.5.2, “Guarding Against Electrostatic Damage,” or any other
applicable ESD protection handbook.