User Manual
Rockwell Automation Publication 23P-IN005A-EN-P - June 2011 7
3. Remove the PE ground screws (2) from the grounding tab on the bottom of the
chassis, and save for reassembly.
4. Remove the mounting screws (6) for the bottom air flow plate, and save for
reassembly.
5. Remove the visible capacitor circuit board mounting screws (4).
PE Ground
Screws (2)
Tightening torque:
2.5 N•m
(22.0 lb•in)
Mounting
Screws (6)
Tightening
torque:
1.0 N•m
(8.9 lb•in)
Visible Mounting
Screws (4)
Tightening torque:
1.0 N•m
(8.9 lb•in)
Hidden Mounting
Screw (1) Under
the Ground Bar
Tightening torque:
1.0 N•m
(8.9 lb•in)