Owner's manual
Rockwell Automation Publication 23P-UM001D-EN-P - July 2012 77
Specifications Appendix A
Figure 37 - Gate Scaling Module Mounting Dimensions Input / Output Connections
Part No. 97331001 - To view drawing, 97331000.
Table 30 - Gate Scaling Module, Part No. 97331001 Weights
Recommended Mounting Hardware: Metric M4, English #8
Engineered byEngineered by
GATE SCALING
MODULE
INPUT OUTPUT
Part No. 97331001
Notes:
Module Depth = 31.0 mm (1.22 in.)
Mounting Holes: 4.25 mm (0.17 in.)
124.0 mm
(4.88 in.)
138.0 mm
(5.43 in.)
60.5 mm
(2.38 in.)
37.25 mm
(1.47 in.)
(Center Diameter)
Gate Scaling Module Gate Scaling Module and Packaging
0.9 kg (0.4 lbs) 1.3 kg (0.6 lbs)
IMPORTANT
When mounting the Gate Scaling Module, washers may be required
because the mounting holes are tapered. If a mounting screw is over
tightened then the cast metal could break.