Owner's manual

Rockwell Automation Publication 23P-UM001D-EN-P - July 2012 71
Appendix
A
Specifications
Stand Alone Regulator
Electrical
Field Bridge
Input Voltage 100VAC…460VAC, ±10%, 50/60 Hz
Control Supply
Input Current 115VAC/1AAC or 230VAC/0.5AAC
Environmental
Operating Temperature 0 ° C to 50 ° C (32 ° F to 122 ° F)
Storage Temperature -25 ° C to 55° C (-13 ° F to 131 ° F)
Relative Humidity 5% to 95%, Non-condensing
Note: Contamination from oils, corrosive vapors and abrasive debris must be
kept out of the enclosure.
Power Dissipation
Gate Amplifier
Electrical
Control Input 120VAC ±10%, 1.9 A, 47-63 Hz
Replacement fuse Littelfuse 312005, 5 A, 250VAC, 3AG Time Delay
or equivalent.
Environmental
Operating Temperature 0 ° C to 50 ° C (32 ° F to 122 ° F)
Storage Temperature -40 ° C to 70 ° C (-40 ° F to 158 ° F)
Relative Humidity 5% to 95%, Non-condensing
Note: Contamination from oils, corrosive vapors and abrasive debris must be
kept out of the enclosure.
Catalog
Number
Power Bridge AC
Input Field Ratings
Total Watts
Loss
[V
AC
] Input [V
AC
] Input [A
AC
] Output [A
DC
][W]
23PMD4 (230 to) 500 (230 to) 460 40 40 303
23PMD7 (230 to) 500 (230 to) 460 70 70 357
23PMF4 (575 to) 690 (230 to) 460 40 40 374
23PMF7 (575 to) 690 (230 to) 460 70 70 428