User guide
Rockwell Automation Publication 23C-IN001B-EN-P - June 2013 109
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N) Chapter 2
Figure 78 - 3.0…50 Hp, 208V AC & 3.0…100 Hp, 460V AC Drives (Sheet 1 of 2) - NEMA/UL Type 4
98D01539
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
01
SH.NEXT
NO.SH.
-
DWG.ENG.
TITLE
CHK. BY
NO.DATE DATE
DR. BY
DATE
THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY
PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC.
APPROVAL
DESIGN REVIEW
FOR MANUFACTURING
AS SHIPPED
AS COMMISSIONED
BYDATE
DATEREV. BY ECN/CR. NO.
43
44
45
46
43
44
45
46
12
SCHEMATIC DRAWING - PF400, STYLE B, NEMA4
3-50HP @ 208VAC, 3-100HP @ 460VAC
98D01539 1
JRF/ACI
11/17/05
JCL/ACI
02/17/06
JFH/ACI
11/17/05
H 12/15/08 AWR
I 4/10/12 JCK
01
"P1" DEFAULT POSITION IS PARKED IN POSITION
"A". FOR PURGE. WITH HAND-OFF-AUTO SWITCH IN
OFF POSITION MOVE "P1" TO POSTION "B".
"P2" DEFAULT POSITION IS PARKED IN POSITION
"A-B". FOR DRIVE TEST IN BYPASS MOVE "P2" TO
POSITION "B-C".
3
OPENING OF FREEZE/FIRE INTERLOCK (IN DRIVE
MODE) WILL REQUIRE MANUAL RESET.
2
1
CONTROL BOARD
STATS
FREEZE/FIRE
IF INTERLOCK USED
REMOVE JUMPER
PURGE
BYPASS
AUTO START
REMOVE JUMPER
IF INTERLOCK USED
INTERLOCKS
31
34
37
31
230V
33
32
1
35
36
38
X1
H1
208V
FU4
RUN/FWD
FUNCTION LOSS
SOFTWARE ENABLE
X2
DOC
63 68 64
1 23
115VAC
T
460V
FU5
H3H2
H4
T
S
R
FU3
FU2
FU1
L23
L22
L21
OLBC
DOC
19
OPTO OUTPUT (AT FREQUENCY)
+ 10VDC
+ 24VDC
ANALOG INPUT #1
ANALOG COM. #1
ANALOG OUTPUT #1 (FREQUENCY 0-10V)
ANALOG OUTPUT #2 (OUT CURRENT 0-10V)
ANALOG INPUT #2
ANALOG COM #2
DIGITAL INPUT 1 (PURGE)
DIGITAL COMMON
DIGITAL INPUT 2 (ANALOG 1 IN)
DIGITAL INPUT 3 (CLEAR FAULT)
DIGITAL COMMON
DIGITAL INPUT 4 (COMM PORT)
OPTO COMMON
DOC
69
54 76
67
981110 151312 14 1716 18
10V 20MA
AI2
10V 20MA10V 20MA
AO1
AO2 AI1
10V 20MA
U
U/T1
VW
SNK
SRC
POWERFLEX 400
#1 RELAY N.O. (READY/FAULT)
#1 RELAY COMMON
#1 RELAY N.C.
#2 RELAY N.O. (MOTOR RUNNING)
#2 RELAY COMMON
#2 RELAY N.C.
RJ-45 SHIELD
R3R120 R2 R5R4 R6
MOTOR
T2
T3
T1
T3
T1
T2
T3
T2
T1
CONN2
C
B
A
P1
3
P2
BA
12
31
1613
2
3332
711
3534
98
3736
410
38
65 114
4544
32
4948
CONTROL PANEL
SEE SHEET 2
CONN1
X2
15 1
61
23
6362
45
6564
67
66 67
L3
G
INCOMING
3
f POWER
L1
L2
C2C1
REACTOR
LINE
B1
A1
B2
A2
A1
B1
C1
65
OPTIONAL
DS1
MAIN DISCONNECT SWITCH
OR
OPTIONAL CIRCUIT BREAKER
THERMOSTAT
TH2
OPTIONAL
WITH ENC.
HEATER
LR
SEE SHEET 2
31A
X2
X3
HAND
SS2
OFF
AUTO
12 13 14
MANUAL
SPEED
P1
OPTIONAL
ENCLOSURE
HEATER
DOC
OL
BC
41
42
43
42 43
41
PARAMETER SETTING CHANGES
PARAMETER DESCRIPTION DEFAULT CHANGE TO
P036 Start Source 3 2-W Lvl Sens" 6 2-W Lvl Sens"
P038
Speed Ref 2 "Analog In 1" 3 "Analog In 2"
P042 Auto Mode 1 "Hnd-Off-Auto"
0 "No Function"
T052
Digital In2 Set
3 "Local"
14 "Anlg 1 InCtrl"
T073
Analog In 2 Sel 0 "Normally Open"
1 "4-20Ma"
A165
Start At Powerup
0 "Disabled"
1 "Enabled"
FU8
GND
MG
V/T2 W/T3
R/L1
S/L2
T/L3
DIC
P1 P2
HTR
ENCLOSURE A/C
7.5-100HP@480VAC
5-50HP@208VAC
ONLY
FU6
A/C
FU7
X1
30
22
30
X2
G
44
BC
39
40
DRIVE
INPUT
CONTACTOR
DIC
39
40
BC
45
50
46
DIC
DOC
51
47
BC
OL
BYPASS
CONTACTOR
DRIVE
OUTPUT
CONTACTOR
DOC
BC
SUPPRESSORS
AS REQUIRED