User guide

Rockwell Automation Publication 23C-IN001B-EN-P - June 2013 105
3 Contactor Full Feature Bypass with Disconnect Package (Style B/N) Chapter 2
Figure 74 - 3.0…50 Hp, 208V AC & 3.0…100 Hp, 460V AC Drives with Line Reactor (Sheet 1 of 2) - NEMA/UL Type 1
98D00757
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
01
DATEREV. BY ECN/CR. NO.
A 11/24/04 JRF
B 5/18/05 JRF
C 6/8/07 REH
D 6/25/08 AWR
E 1/31/11 JLD
F 4/10/12 JCK
APPROVAL
DESIGN REVIEW
FOR MANUFACTURING
AS SHIPPED
AS COMMISSIONED
BYDATE
SH.NEXT
NO.SH.
-
DWG.ENG.
TITLE
CHK. BY
NO.DATE DATE
DR. BY
DATE
THIS DRAWING IS THE PROPERTY OF ROCKWELL AUTOMATION, INC.
OR ITS SUBSIDIARIES AND MAY NOT BE COPIED, USED OR DISCLOSED FOR ANY
PURPOSE EXCEPT AS AUTHORIZED IN WRITING BY ROCKWELL AUTOMATION, INC.
12
SCHEMATIC DRAWING - PF400, STYLE B, W/LINE REACTOR
3-50HP @ 208VAC & 3-100HP @ 460VAC
98D00757
JRF/ACI
5/17/04
JFH/ACI
5/17/04
S TATS
FREEZE/FIRE
IF INTERLOCK USED
REMOVE JUMPER
BC
OL
PURGE
DOC
BYPASS
AUTO START
INTERLOCKS
31
34
37
31
230V
32
1
33
36
35
38
43
42
41
H1
208V
X1
FU4
460V
115VAC
H3H2
T1
H4
X2
FU5
C1
B1
A1
DIC
DS1
MAIN DISCONNECT SWITCH
FU3
FU2
FU1
L3
L2
L1
OLBC
MOTOR
T2
T3
T1
T2
T3
T3
T2
T1
T1
CONN2
REMOVE JUMPER
IF INTERLOCK USED
C
B
A
2
P1
3
P2
BA
CP1
CONTROL PANEL
12
31
1613
3332
711
3534
98
3736
410
4138
65
4342
114
4544
32
4948
CONN1
X2
15
X2
1
61
23
6362
OPENING OF FREEZE/FIRE INTERLOCK (IN DRIVE
MODE) WILL REQUIRE MANUAL RESET.
1
"P2" DEFAULT POSITION IS PARKED IN POSITION
"A-B". FOR DRIVE TEST IN BYPASS MOVE "P2" TO
POSITION "B-C".
"P1" DEFAULT POSITION IS PARKED IN POSITION
"A". FOR PURGE. WITH HAND-OFF-AUTO SWITCH IN
OFF POSITION MOVE "P1" TO POSTION "B".
3
2
45
6564
67
66 67
DOC
63 68 64
T/L3
S/L2
R/L1
DOC
69 65 67
W/T3
DOC
V/T2U/T1
U VW
POWERFLEX 400
P1 P2
INCOMING
3
f POWER
DM1
SEE SH.2
(FOR CONTROL PANEL SCHEMATIC)
10V 20MA
RUN/FWD
FUNCTION LOSS
SOFTWARE ENABLE
DIGITAL INPUT 1 (PURGE)
DIGITAL COMMON
DIGITAL INPUT 2 (LOCAL)
DIGITAL INPUT 3 (CLEAR FAULT)
DIGITAL COMMON
DIGITAL INPUT 4 (COMM PORT)
1 324 75 6 89
10V 20MA
CONTROL BOARD
AO2
10V 20MA
AO1 AI1
ANALOG COM. #1
ANALOG OUTPUT #2 (OUTPUT CURRENT 0-10V)
ANALOG OUTPUT #1 (FREQUENCY 0-10V)
ANALOG INPUT #1
+ 10VDC
+ 24VDC
ANALOG INPUT #2
#1 RELAY N.O. (READY/FAULT)
ANALOG COM #2
OPTO OUTPUT (AT FREQUENCY)
#1 RELAY COMMON
#1 RELAY N.C.
#2 RELAY N.O. (MOTOR RUNNING)
#2 RELAY COMMON
#2 RELAY N.C.
RJ-45 SHIELD
OPTO COMMON
151110 12 13 14 16 17 1918 20 R3R1 R2 R4 R5 R6
SRC
10V 20MA
AI2
SNK
MGG
X2
C1
B1
A1
C2
B2
A2
T
S
R
LINE REACTOR
L23
L22
L21
44
BC
39
40
DRIVE
INPUT
CONTACTOR
DIC
39
40
BC
45
50
46
DIC
DOC
51
47
BC
OL
BYPASS
CONTACTOR
DRIVE
OUTPUT
CONTACTOR
DOC
BC
SUPPRESSORS
AS REQUIRED