3-64 Programming and Parameters
PowerFlex 400 Adjustable Frequency AC Drive FRN 1.xx - 7.xx User Manual
Publication 22C-UM001I-EN-P
Advanced Display Group (continued)
d318 [Output Powr Fctr] Related Parameter(s): T055, T056, T060, T061, T065, T066
The angle in electrical degrees between motor voltage and motor current.
Values Default: Read Only
Min/Max: 0.0/180.0 deg
Display: 0.1 deg
d319 [Testpoint Data] Related Parameter(s): A196
The present value of the function selected in A196 [Testpoint Sel].
Values Default: Read Only
Min/Max: 0/FFFF
Display: 1 Hex
d320 [Control SW Ver]
Main Control Board software version.
Values Default: Read Only
Min/Max: 1.00/99.99
Display: 0.01
d321 [Drive Type]
Used by Rockwell Automation field service personnel.
d322 [Output Speed] Related Parameter(s): P034
Displays current output frequency in percent (%). The scale is 0% at 0.00 Hz to 100.0% at P034
[Maximum Freq].
Values Default: Read Only
Min/Max: 0.0/100.0%
Display: 0.1%
d323 [Output RPM] Related Parameter(s): A199
Displays current output frequency in RPM. The scale is based on A199 [Motor NP Poles].
Values Default: Read Only
Min/Max: 0/24000 RPM
Display: 1 RPM