Quick Start FRN 5.xx - 6.xx User Manual
Italiano-17
A065 [Sel. uscita anlg] 0/23 1 0
A066 [Uscita anlg alta] 0/800% 1% 100%
A067 [Tempo accel. 2] 0,0/600,0 sec 0,1 sec 20,0 sec
A068 [Tempo decel. 2] 0,1/600,0 sec 0,1 sec 20,0 sec
A069 [Freq interna] 0,0/400,0 Hz 0,1 Hz 0,0 Hz (per gli
inverter IP66,
NEMA/UL
Type 4X)
60,0 Hz (per
inverter IP20)
A070
A071
A072
A073
A074
A075
A076
A077
[Freq. predef. 0]
(1)
[Freq. predef. 1]
[Freq. predef. 2]
[Freq. predef. 3]
[Freq. predef. 4]
[Freq. predef. 5]
[Freq. predef. 6]
[Freq. predef. 7]
0,0/400,0 Hz 0,1 Hz 0,0 Hz
5,0 Hz
10,0 Hz
20,0 Hz
30,0 Hz
40,0 Hz
50,0 Hz
60,0 Hz
(1)
Per attivare [Freq predef 0] impostare il parametro P038 [Rif velocità] sull’opzione 4.
A078 [Frequenza jog] 0,0/[Frequenza max] 0,1 Hz 10,0 Hz
A079 [Accel/decel/ jog] 0,1/600,0 sec 0,1 sec 10,0 sec
A080 [Tempo freno CC] 0,0/99,9 sec 0,1 sec 0,0 sec
Impostando 99,9 sec. = Continuo
A081 [Liv freno CC] 0,0/(Ampere inverter ×
1,8)
0,1 Amp Ampere ×
0,05
A082 [Sel resis freno d.] 0/99 0 = “Disabilitato”
1 = “Res RA norm”
2 = “No protez.”
3-99 = % ciclo di carico
0
A083 [% Curva S] 0/100% 1% 0%
(disabilitato)
N. Parametro Min/Max Display/Opzioni
Valore
predefinito
Opzione Gamma uscita
Valore di uscita
minimo
Valore di uscita massimo
[Uscita anlg alta]
Posizione
microinterruttore
0 “FreqUsc 0-10” 0-10 V 0 V = 0 Hz P035 [Frequenza max] 0-10 V
1 “CorrUsc 0-10” 0-10 V 0 V = 0 ampere 200% FLA nominale inverter 0-10 V
2 “VoltUsc 0-10” 0-10 V 0 V = 0 Volt 120% volt uscita nominale inverter 0-10 V
3 “PotUsc 0-10” 0-10 V 0 V = 0 kW 200% potenza nominale inverter 0-10 V
4 “DatiPr 0-10” 0-10 V 0 V = 0000 65535 (FFFF esadecimali) 0-10 V
5 “FreqUsc 0-20” 0-20 mA 0 mA = 0 Hz P035 [Frequenza max] 0-20 mA
6 “CorrUsc 0-20” 0-20 mA 0 mA = 0 ampere 200% FLA nominale inverter 0-20 mA
7 “VoltUsc 0-20” 0-20 mA 0 mA = 0 Volt 120% volt uscita nominale inverter 0-20 mA
8 “PotUsc 0-20” 0-20 mA 0 mA = 0 kW 200% potenza nominale inverter 0-20 mA
9 “DatiPr 0-20” 0-20 mA 0 mA = 0000 65535 (FFFF esadecimali) 0-20 mA
10 “FreqUsc 4-20” 4-20 mA 4 mA = 0 Hz P035 [Frequenza max] 0-20 mA
11 “CorrUsc 4-20” 4-20 mA 4 mA = 0 ampere 200% FLA nominale inverter 0-20 mA
12 “VoltUsc 4-20” 4-20 mA 4 mA = 0 Volt 120% volt uscita nominale inverter 0-20 mA
13 “PotUsc 4-20” 4-20 mA 4 mA = 0 kW 200% potenza nominale inverter 0-20 mA
14 “DatiPr 4-20” 4-20 mA 4 mA = 0000 65535 (FFFF esadecimali) 0-20 mA
15 “CoppUsc 0-10” 0-10 V 0 V = 0 ampere 200% FLA nominale inverter 0-10 V
16 “CoppUsc 0-20” 0-20 mA 0 mA = 0 ampere 200% FLA nominale inverter 0-20 mA
17 “CoppUsc 4-20” 4-20 mA 4 mA = 0 ampere 200% FLA nominale inverter 0-20 mA
18 “Prest 0-10” 0-10 V 0 V = 0% 100,0% impostazione setpoint 0-10 V
19 “Prest 0-20” 0-20 mA 0 mA = 0% 100,0% impostazione setpoint 0-20 mA
20 “Prest 4-20” 4-20 mA 4 mA = 0% 100,0% impostazione setpoint 0-20 mA
21 “FreqMin 0-10” 0-10 V 0V = freq min. P035 [Frequenza max] 0-10 V
22 “FreqMin 0-20” 0-20 mA 0 mA = freq min. P035 [Frequenza max] 0-20 mA
23 “FreqMin 4-20” 4-20 mA 4 mA = freq min. P035 [Frequenza max] 0-20 mA
Stato ingresso
di ingr dig 1
(morsetto I/O 05)
Stato ingresso
di ingr dig 2
(morsetto I/O 06)
Stato ingresso
di ingr dig 3
(morsetto I/O 07)
Sorgente della
frequenza
Parametro
di accelerazione/
decelerazione usato
(2)
0 0 0 [Freq. predef. 0] [Tempo accel. 1] / [Tempo decel. 1]
1 0 0 [Freq. predef. 1] [Tempo accel. 1] / [Tempo decel. 1]
0 1 0 [Freq. predef. 2] [Tempo accel. 2] / [Tempo decel. 2]
1 1 0 [Freq. predef. 3] [Tempo accel. 2] / [Tempo decel. 2]
0 0 1 [Freq. predef. 4] [Tempo accel. 1] / [Tempo decel. 1]
1 0 1 [Freq. predef. 5] [Tempo accel. 1] / [Tempo decel. 1]
0 1 1 [Freq. predef. 6] [Tempo accel. 2] / [Tempo decel. 2]
1 1 1 [Freq. predef. 7] [Tempo accel. 2] / [Tempo decel. 2]
(2)
Quando un ingresso digitale viene impostato su “Accel. 2 e decel. 2” e l’ingresso è attivo, quell’ingresso sovrascrive le
impostazioni contenute in questa tabella.
Per ulteriori informazioni sui parametri, consultare il manuale dell’utente di PowerFlex 40.