Instruction Manual
Rockwell Automation Publication 23B-IN001K-EN-P - September 2013 23
PowerFlex 40 Standard Configured Drive Standard Features and Options Chapter 1
Clear Fault Push Button (Code S23)
This option provides a factory installed 800F Clear Fault push button.
Component Specifications
This option is not compatible with Code S7.
Quick Disconnects
DeviceNet Quick Disconnect - Bottom (Code E22)
A Brad Harrison, 5 pin, bulkhead, male receptacle is provided and wired to the
drive mounted DeviceNet module. The connector is located through the bottom
of the enclosure providing a quick disconnect. This option is designed to enhance
the DeviceNet offering (Position 12, Code D) and is not compatible with
options 4, C, E, P (Position 12), or E23.
To r e v i e w s c h e m a t i c r e f e r t o Figure 4 on page 31
.
To review layout refer to Figure 25 on page 52
.
For NEMA/UL Type 4 or less stringent environments, the outer connector
construction is made of plastic designed to withstand washdown conditions.
DeviceNet Quick Disconnect - Left Side (Code E23)
A Brad Harrison, 5 pin, bulkhead, male receptacle is provided and wired to the
drive mounted DeviceNet module. The connector is located through the left side
of the enclosure providing a quick disconnect. This option is designed to enhance
the DeviceNet offering (Position 12, Code D) and is not compatible with
options 4, C, E, P (Position 12), or E22.
To r e v i e w s c h e m a t i c r e f e r t o Figure 4 on page 31
.
To review layout refer to Figure 25 on page 52
.
For NEMA/UL Type 4 or less stringent environments the outer connector
construction is made of plastic designed to withstand washdown conditions.
Bulletin 800F Devices IEC style, Internationally rated
Meet IP65/IP66 and NEMA/UL Type 4/4X/13
UL Listed, CSA Certified
10 amp contacts
Screw terminals, 0.3…3.5 mm
2
(22…12 AWG) maximum
Clear Fault Push Button: Flush head, Black, 1 N.O. contact
Legend Plate 30 x 50 mm, Black with white lettering
Wiring 0.8 mm
2
(18 AWG), Blue
Schematic Figure 17 on page 44