User manual
AC Adjustable Frequency Drives
PowerFlex 700
84
Input and Output Line Reactors - 240V, 60 Hz, Three-Phase, 3% Impedance
Drive Cat. No. Duty Hp
Input Line Reactor 7 Output Line Reactor 7
IP00 (Open Style) IP11 (NEMA Type 1) IP00 (Open Style) IP11 (NEMA Type 1)
Cat. No. Cat. No. Cat. No. Cat. No.
20BB2P2 Heavy Duty 0.33 1321-3R2-D 1321-3RA2-D 1321-3R2-D 1321-3RA2-D
20BB2P2 Normal Duty 0.5 1321-3R2-D 1321-3RA2-D 1321-3R2-D 1321-3RA2-D
20BB4P2 Heavy Duty 0.75 1321-3R4-A 1321-3RA4-A 1321-3R4-A 1321-3RA4-A
20BB4P2 Normal Duty 1 1321-3R4-A 1321-3RA4-A 1321-3R4-A 1321-3RA4-A
20BB6P8 Heavy Duty 1.5 1321-3R8-B 1321-3RA8-B 1321-3R8-A 1321-3RA8-A
20BB6P8 Normal Duty 2 1321-3R8-A 1321-3RA8-A 1321-3R8-A 1321-3RA8-A
20BB9P6 Heavy Duty 2 1321-3R8-A 1321-3RA8-A 1321-3R12-A 1321-3RA12-A
20BB9P6 Normal Duty 3 1321-3R12-A 1321-3RA12-A 1321-3R12-A 1321-3RA12-A
20BB015 Heavy Duty 3 1321-3R12-A 1321-3RA12-A 1321-3R18-A 1321-3RA18-A
20BB015 Normal Duty 5 1321-3R18-A 1321-3RA18-A 1321-3R18-A 1321-3RA18-A
20BB022 Heavy Duty 5 1321-3R18-A 1321-3RA18-A 1321-3R25-A 1321-3RA25-A
20BB022 Normal Duty 7.5 1321-3R25-A 1321-3RA25-A 1321-3R25-A 1321-3RA25-A
20BB028 Heavy Duty 7.5 1321-3R25-A 1321-3RA25-A 1321-3R35-A 1321-3RA35-A
20BB028 Normal Duty 10 1321-3R35-A 1321-3RA35-A 1321-3R35-A 1321-3RA35-A
20BB042 Heavy Duty 10 1321-3R35-A 1321-3RA35-A 1321-3R45-A 1321-3RA45-A
20BB042 Normal Duty 15 1321-3R45-A 1321-3RA45-A 1321-3R45-A 1321-3RA45-A
20BB052 Heavy Duty 15 1321-3R45-A 1321-3RA45-A 1321-3R55-A 1321-3RA55-A
20BB052 Normal Duty 20 1321-3R55-A 1321-3RA55-A 1321-3R55-A 1321-3RA55-A
20BB070 Heavy Duty 20 1321-3R55-A 1321-3RA55-A 1321-3R80-A 1321-3RA80-A
20BB070 Normal Duty 25 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A
20BB080 Heavy Duty 25 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A
20BB080 Normal Duty 30 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A
20BB104 Heavy Duty 30 1321-3R80-A 1321-3RA80-A 1321-3R80-A 1321-3RA80-A
20BB104 Normal Duty 40 1321-3R100-A 1321-3RA100-A 1321-3R100-A 1321-3RA100-A
20BB130 Heavy Duty 40 1321-3R100-A 1321-3RA100-A 1321-3R100-A 1321-3RA100-A
20BB130 Normal Duty 50 1321-3R130-A 1321-3RA130-A 1321-3R130-A 1321-3RA130-A
20BB154 Heavy Duty 50 1321-3R130-A 1321-3RA130-A 1321-3R130-A 1321-3RA130-A
20BB154 Normal Duty 60 1321-3R160-A 1321-3RA160-A 1321-3R160-A 1321-3RA160-A
20BB192 Heavy Duty 60 1321-3R160-A 1321-3RA160-A 1321-3R160-A 1321-3RA160-A
20BB192 Normal Duty 75 1321-3R200-A 1321-3RA200-A 1321-3R200-A 1321-3RA200-A
20BB260 Heavy Duty 75 1321-3R200-A 1321-3RA200-A 1321-3R200-A 1321-3RA200-A
20BB260 Normal Duty 100 1321-3RB250-A 1321-3RAB250-A 1321-3RB250-A 1321-3RAB250-A
7 Input line reactors were sized based on the NEC fundamental motor amps. Output line reactors were sized based on the VFD rated output currents.