User manual
AC Adjustable Frequency Drives
PowerFlex 70
67
Packaged Drives Programs
Product Selection (continued)
Optional (Choose Any or All)
Output
Contactor
(-KM)
✶
Manual Bypass
Choose One
(-BM1 or -BM2) Adjustable Range in
Amps7♣
➤
Drive Mounted
Brake Resistor
(-BR)
Line Reactor
Input, 3%,
Normal Duty
(-LRN)
Line Reactor
Input, 3%,
Heavy Duty
(-LRH)
Line Reactor
Output, 3%,
Normal Duty
(-LQN)
Line Reactor
Output, 3%,
Heavy Duty
(-LQH)
115V Control
Power,
Drive/Options
Only
(-CF)‡
Area Factor§
ND
(-BM1)
HD
(-BM2)
Area Factor Area Factor Area Factor Area Factor Area Factor Area Factor Area Factor
208V ac, Three-Phase Drives
A26 2.4…4.0 1.6…2.4 A54 A0 A58 A58 A58 A58 A16
A26 4.0…6.0 2.4…4.0 A54 A0 A58 A58 A58 A58 A16
A26 6.0…10 6.0…10 A54 A0 A58 A58 A58 A58 A16
A26 10…16 6.0…10 A54 A0 A58 A58 A58 A58 A16
A26 16…24 10…16 A54 A0 A58 A58 A58 A58 A16
A26 18…30 16…24 A54 A0 A60 A60 A60 A60 A16
A26 30…45 18…30 A54 A0 A60 A60 A60 A60 A16
240V ac, Three-Phase Drives
A26 1.6…2.4 1.6…2.4 A54 A0 A58 A58 A58 A58 A16
A26 4.0…6.0 2.4…4.0 A54 A0 A58 A58 A58 A58 A16
A26 6.0…10 4.0…6.0 A54 A0 A58 A58 A58 A58 A16
A26 6.0…10 6.0…10 A54 A0 A58 A58 A58 A58 A16
A26 10…16 6.0…10 A54 A0 A58 A58 A58 A58 A16
A26 16…24 10…16 A54 A0 A60 A58 A60 A60 A16
A26 18…30 18…30 A54 A0 A60 A60 A60 A60 A16
480V ac, Three-Phase Drives
A26 1.0…1.6 0.6…1.0 A54 A0 A58 A58 A58 A58 A16
A26 1.6…2.4 1.0…1.6 A54 A0 A58 A58 A58 A58 A16
A26 2.4…4.0 2.4…4.0 A54 A0 A58 A58 A58 A58 A16
A26 4.0…6.0 2.4…4.0 A54 A0 A58 A58 A58 A58 A16
A26 6.0…10 4.0…6.0 A54 A0 A58 A58 A58 A58 A16
A26 10…16 6.0…10 A54 A0 A58 A58 A58 A58 A16
A26 10…16 10…16 A54 A0 A58 A58 A58 A58 A16
A26 16…24 10…16 A54 A0 A58 A58 A60 A60 A16
A26 18…30 18…30 A54 A0 A58 A58 A60 A60 A16
600V ac, Three-Phase Drives
A26 0.6…1.0 0.6…1.0 A54 N/A A58 A58 A58 A58 A16
A26 1.6…2.4 1.0…1.6 A54 N/A A58 A58 A58 A58 A16
A26 2.4…4.0 1.6…2.4 A54 N/A A58 A58 A58 A58 A16
A26 2.4…4.0 2.4…4.0 A54 N/A A58 A58 A58 A58 A16
A26 6.0…10 4.0…6.0 A54 N/A A58 A58 A58 A58 A16
A26 6.0…10 6.0…10 A54 N/A A58 A58 A58 A58 A16
A26 10…16 6.0…10 A54 N/A A58 A58 A58 A58 A16
A26 16…24 10…16 A54 N/A A58 A58 A60 A60 A16
A26 16…24 16…24 A54 N/A A58 A58 A60 A60 A16
✶ Option -JF is required. Cannot be used with -BM1, BM2 or BA.
7 Cannot be used with -KM. -BM1 cannot be used with -BM2. Bypass duty cycle must match drive duty cycle.
‡ This option does not provide 115V AC control interface to the drive or -MH option.
Applies to NEMA Type 1 drives only.
♣ Option includes “Drive-Off-Bypass” selector switch.
➤ Requires -CF option or customer-supplied 115V.