18
Dynamic Brake Resistors
Drive Ratings Minimum Resistance
Cat. No.✶Input Voltage kW Hp
Ω
120V 50/60 Hz
1-Phase
0.4 0.5 48
AK-R2-091P500
0.75 1.0 48
AK-R2-091P500
1.1 1.5 48 AK-R2-091P500
240V 50/60 Hz
1-Phase
0.4 0.5 48
AK-R2-091P500
0.75 1.0 48 AK-R2-091P500
1.5 2.0 48
AK-R2-091P500
2.2 3.0 32 AK-R2-047P500
240V 50/60 Hz
3-Phase
0.4 0.5 48
AK-R2-091P500
0.75 1.0 48 AK-R2-091P500
1.5 2.0 48
AK-R2-091P500
2.2 3.0 32 AK-R2-047P500
3.7 5.0 19
AK-R2-047P500
5.5 7.5 13 AK-R2-030P1K2
7.5 10 10
AK-R2-030P1K2
480V 50/60 Hz
3-Phase
0.4 0.5 97
AK-R2-360P500
0.75 1.0 97
AK-R2-360P500
1.5 2.0 97 AK-R2-360P500
2.2 3.0 97
AK-R2-120P1K2
4.0 5.0 77 AK-R2-120P1K2
5.5 7.5 55
AK-R2-120P1K2
7.5 10 39
AK-R2-120P1K2
11 15 24
AK-R2-120P1K2 7
600V 50/60 Hz
3-Phase
0.75 1.0 120
AK-R2-360P500
1.5 2.0 120
AK-R2-360P500
2.2 3.0 82 AK-R2-120P1K2
4.0 5.0 82
AK-R2-120P1K2
5.5 7.5 51 AK-R2-120P1K2
7.5 10 51
AK-R2-120P1K2
11 15 51
AK-R2-120P1K2 7
✶ Resistors listed in this table are rated 5% duty cycle.