User manual
AC Adjustable Frequency Drives
PowerFlex 700S
129
DC Input Drives
DC input for Frames 1…4 use the same code as AC input. Refer to the tables below for frames 5 and 6.
325V dc Input Drives
325V dc Input ✶ 280V dc Input IP20, NEMA Type 1
Frame
Size
Output Amps
Normal
Duty Hp
Heavy
Duty Hp
Output Amps
Normal
Duty kW
Heavy
Duty kW
Cat. No.
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
20D…
104 (80)7
115 (120) 175 (160) 40 30 120 (92) 132 (138) 175 (175) 30 22 Y
N104A0ENNANANE 5
130 (104)7
143 (156) 175 (175) 50 40 130 (104) 143 (156) 175 (175) 37 30 Y N130A0ENNANANE 5
154 (130)7
169 (195) 231 (260) 60 50 177 (150) 195 (225) 266 (300) 45 37 Y
N154A0ENNANANE 6
192 (154)7
211 (231) 288 (308) 75 60 221 (177) 243 (266) 308 (308) 55 45 Y N192A0ENNANANE 6
260 (205)7
286 (305) 390 (410) 100 75 260 (205) 286 (305) 390 (410) 66 55 Y N260A0ENNANANE 6
✶ Catalog number corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
7 Frame 5 and 6 drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis). The drive may be
operated at either rating.
650V dc Input Drives
650V dc Input ✶ 540V dc Input
DC Pre-
charge
IP20, NEMA Type 1
Frame
Size
Output Amps
Normal
Duty Hp
Heavy
Duty Hp
Output Amps
Normal
Duty kW
Heavy
Duty kW
Cat. No.
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
20D…
96 (77)7
106 (116) 144 (154) 75 60 105 (85) 116 (128) 158 (170) 55 45 N
J096A0ENNANANE 5
96 (77)7
106 (116) 144 (154) 75 60 105 (85) 116 (128) 158 (170) 55 45 Y
R096A0ENNANANE 5
125 (96)7
138 (144) 163 (168) 100 75 125 (96) 138 (144) 163 (168) 55 45 N J125A0ENNANANE 5
125 (96)7
138 (144) 163 (168) 100 75 125 (96) 138 (144) 163 (168) 55 45 Y R125A0ENNANANE 5
156 (125)7
172 (188) 233 (250) 125 100 170 (140) 187 (210) 255 (280) 90 75 N
J156A0ENNANANE 6
156 (125)7
172 (188) 233 (250) 125 100 170 (140) 187 (210) 255 (280) 90 75 Y R156A0ENNANANE 6
180 (156)7
198 (234) 270 (312) 150 125
205 (170)
220 (255) 289 (313) 110 90 N J180A0ENNANANE 6
180 (156)7
198 (234) 270 (312) 150 125
205 (170)
220 (255) 289 (313) 110 90 Y
R180A0ENNANANE 6
248 (180)7
➤
273 (270) 372 (360) 200 150
260 (205)
➤
286 (308) 390 (410) 132 110 N J248A0ENNANANE 6
248 (180)7
➤
273 (270) 372 (360) 200 150
260 (205)
➤
286 (308) 390 (410) 132 110 Y R248A0ENNANANE 6
✶ Catalog number corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
7 Frame 5 and 6 drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis). The drive may be
operated at either rating.
➤ Rating is limited to 45°C surrounding air.
Rating is limited to 40°C surrounding air.
810V dc Input Drives
810V dc Input ✶ 690V dc Input
DC Pre-
charge
IP20, NEMA Type 1
Frame
Size
Output Amps
Normal
Duty Hp
Heavy
Duty Hp
Output Amps
Normal
Duty kW
Heavy
Duty kW
Cat. No.
Cont. 1 Min. 3 Sec. Cont. 1 Min. 3 Sec.
20D…
99 (77)7
109 (116) 126 (138) 100 75
98 (82)
108 (123) 127 (140) 90 75 Y
T099A0ENNANANE 5
144 (125)7
158 (188) 216 (250) 150 125 142 (119) 156 (179) 213 (238) 132 110 Y T144A0ENNANANE 6
✶ Catalog number corresponds to output amps in these columns. Drive must be programmed to lower voltage to obtain higher currents shown at right.
7 Frame 5 and 6 drives have dual current ratings; one for normal duty applications, and one for heavy duty applications (in parenthesis). The drive may be
operated at either rating.
Rating is limited to 40°C surrounding air.