Owner manual
148 Rockwell Automation Publication 20Y-UM001E-EN-P - July 2014
Appendix B HIM Overview
Parameter Menu
See Viewing and Editing Parameters on page 149.
Device Select Menu
Use this menu to access parameters in connected peripheral devices.
Memory Storage Menu
AFE data can be saved to, or recalled from, HIM sets. HIM sets are files stored in
permanent nonvolatile HIM memory.
Start-up Menu
See Chapter 3.
Preferences Menu
The HIM and AFE have features that you can customize.
The AFE is initially set to Basic Parameter View. To view all parameters, set
parameter 196 [ParamAccessLvl] to option ‘1’ (Advanced). Parameter 196 is not
affected by the Reset to Defaults function.
Option Description
HIM Copycat
Device -> HIM
Device <- HIM
Save data to a HIM set, load data from a HIM set to active AFE
memory, or delete a HIM set.
Reset To Defaults Restore the AFE to its factory-default settings.
Option Description
AFE Identity Add text to identify the AFE.
Change Password Enable/disable or modify the password.
User Dspy Lines Select the display, parameter, scale, and text for the User Display. The User Display is two
lines of user-defined data that appears when the HIM is not being used for programming.
User Dspy Time Set the wait time for the User Display or enable/disable it.
User Dspy Video Select Reverse or Normal video for the Frequency and User Display lines.
Reset User Dspy Return all the options for the User Display to factory default values.