Owner manual
214 Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 7 PowerFlex 700AFE Drive - Frame 10 Procedures
LCL Filter Section
The LCL filter provides the filtering to minimize the harmonic content
originating from the inverter section (PWM frequency) from interacting with
the AC grid.
Replacement procedures for these frame 10 AFE LCL filter fan system parts are
included in this chapter.
Removing the LCL Filter Protective Cover
1. Review the General Precautions on page 17.
2. Remove power from the AFE. See Remove Power from the AFE on page
192
.
3. Remove the sixteen T25 Torx self-tapping cover screws.
Cat. No. Part Description Page
20-PP20202
or SK-Y1-F11-F10
Fuse for fan system 215
SK-Y1-DCPS1-D460 DC fan power supply assembly - 400/480V (older version) 215
SK-Y1-DCPS1-F325 DC fan power supply assembly - 600/690V (older version) 215
SK-Y1-DCPS2-F10 DC fan power supply circuit board upgrade kit - (newer version) 219
SK-H1-DCFANBD1
(1)
(1) Only use this circuit board if you are replacing a newer version circuit board (same catalog number).
Main DC fan power supply circuit board 225
SK-Y1-DCFAN1 Main DC fan assembly 230