Owner manual
Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014 135
PowerFlex 700H and 700S Drives - Frame 13 Procedures Chapter 5
Move the Control Frame, and Remove the Screens, Airflow Plates,
and Protective Covers
You may need to move the control frame based on the mounting location. You
must remove the screens, air flow plate and protective covers from the drive in
order to access fan system components on the drive power structure. Follow these
steps to move the control frame and remove the screens, airflow plate and
protective covers.
1. Review the General Precautions on page 17
.
2. Remove power from the drive. See Remove Power from the Drive on page
134
.
3. If moving the control frame from a DC input drive with pre-charge
interlock, disconnect the wiring from terminal strip X50.
4. Loosen the two hexalobular screws that secure the control frame to the
enclosure and swing the control frame away from the drive.
T20
3.0 N•m (27 lb•in)
4
3