11. Secure the new AC fan capacitor to the new bracket using the M12 nut
and lock washer provided in the kit.
12. Secure the new capacitor bracket assembly to the AC fan inverter assembly
using the two M5 x 10 mm POZIDRIV screws provided in the kit.
13. Install the AC fan inverter assembly in the reverse order of removal.
Nut Washer Bracket Capacitor
Bracket Front
View
12 mm
5 N
•m (44 lb•in)
12
PZ2
4 N
•m (35 lb•in)