Owner manual
104 Rockwell Automation Publication PFLEX-IN029B-EN-P - August 2014
Chapter 3 PowerFlex 700H and 700S Drives - Frame 11 Procedures
order to clear the sheet metal on the frame, and pull the fan assembly off
the positioning pins and out of the drive.
6. Remove the M8 x 16 mm hexagonal socket screw that secures the fan
capacitor and fuse holder adapter bracket to the Phase V AC fan inverter
assembly and remove the bracket. Save this bracket for reuse.
4
5
T30
4.5 N•m (39.8 lb•in)
8 mm
12 N
•m (106 lb•in)
6