Table 83 - 575V AC Input Drives
Table 84 - 690V AC Input Drives
Frame
Drive
Current
Rating
Code
DC
Amps
AC
Line
Amps
Hp Dynamic
Brake
Resistor Kit
Cat. No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB
Resistor
Size
(Watts)
Brake
Amps
Required
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs
Cat. No.
(3)
Drive w/No Dynamic Brake Drive w Dynamic Brake
B 067 67.5 55.1 50
(1)
600 5.93 ABB_EHDB220C2P-1L2S ABB_EHDB220C-1L22SS
(4)
101 101 83 75 600 3.95 ABB_EHDB220C2P-1L2S ABB_EHDB220C-1L22SS
135 135 110 100 600 2.96 ABB_EHDB220C2P-1L2S ABB_EHDB220C-1L22SS
270 270 221 200 600 1.48 ABB_EHDB360C2P-1L2S ABB_EHDB360C-1L22SS
405 405 331 300 600 0.988 ABB_EHDB520C2P-1L2S ABB_EHDB520C-1L22SS
C 540 540 441 400 600 0.741 ABB_EHDB650C2P-1L2S ABB_EHDB650C-1L22SS
675 675 551 500 600 0.593 ABB_EHDB800C2P-1L2S ABB_EHDB800C-1L22SS
D 810 810 662 600 600 0.494 ABB_EHDB960C2P-1L2S ABB_EHDB960C-1L22SS
1K0 1080 882 800 600 0.370 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K2 1215 993 900 600 0.329 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K3 1350 1103 1000 600 0.296 CUTLER-HAMMER_6702ED636-2 (Qty 2) CUTLER-HAMMER_6702ED636-2 (Qty 1)
1K6 1688 1379 1250 600 0.237 CUTLER-HAMMER_6702ED636-2 (Qty 2) CUTLER-HAMMER_6702ED636-2 (Qty 1)
(1) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(2) Coil voltage = 115V AC, 50/60Hz.
(3) See DC Contactor Crimp Lug Kit Specifications on page 250
for more information.
(4) Wire and Lug size dependant on enclosure dimensions and local codes.
Frame
Drive
Current
Rating
Code
DC
Amps
AC
Line
Amps
Hp Dynamic
Brake
Resistor Kit
Cat. No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB
Resistor
Size
(Watts)
Brake
Amps
Required
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs
Cat. No.
(3)
Drive w/No Dynamic Brake Drive w Dynamic Brake
C 452 452 369 400
(1)
700 1.03 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
(4)
565 565 462 500 700 0.826 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
D 678 678 554 600 700 0.688 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
791 791 646 700 700 0.590 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
904 904 739 800 700 0.516 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K0 1017 831 900 700 0.459 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K1 1130 923 1000 700 0.413 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K2 1243 1016 1100 700 0.375 SIEMENS-MFG_14-193-101-58-2 (Qty 2) SIEMENS-MFG_14-193-101-58-2 (Qty 1)
1K4 1413 1154 1250 700 0.330 CUTLER-HAMMER_6702ED636-2 (Qty 2) CUTLER-HAMMER_6702ED636-2 (Qty 1)
1K5 1582 1292 1400 700 0.295 CUTLER-HAMMER_6702ED636-2 (Qty 2) CUTLER-HAMMER_6702ED636-2 (Qty 1)
(1) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(2) Coil voltage = 115V AC, 50/60Hz.
(3) See DC Contactor Crimp Lug Kit Specifications on page 244
for more information.
(4) Wire and Lug size dependant on enclosure dimensions and local codes.