Owner's manual

Rockwell Automation Publication 20P-UM001I-EN-P - February 2013 245
Supplemental Drive Information Appendix A
Alternate Dynamic Brake
Resistor Kits and DC Output
Contactors
The following alternate dynamic brake resistor kits and/or DC output contactors
may be used with the corresponding PowerFlex DC drives but must be sourced
separately from the drive.
Table 81 - 230V AC Input Drives
Table 82 - 460V AC Input Drives
Frame
Drive
Current
Rating
Code
DC
Amps
AC
Line
Amps
Hp Dynamic Brake Resistor
Kit Cat. No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB
Resistor
Size
(Watts)
Brake
Amps
Required
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs Cat.
No.
(3)
Drive w/No Dynamic Brake Drive w Dynamic Brake
B 360 360 294 100 1370-DBL76 240 1.4 290 171.43 ABB_EHDB360C2P-1L2S ABB_EHDB360C-1L22SS
(4)
434 434 355 125 CUTLER-HAMMER_G3AP50
(Qty 4 - two in series, two in
parallel)
240 0.5 1458 651 ABB_EHDB520C2P-1L2S ABB_EHDB520C-1L22SS
C 521 521 426 150 HUBBELL_Y139W322GB 240 0.322 6221 781
700 700 572 200
(1)
240 ABB_EHDB800C2P-1L2S ABB_EHDB800C-1L22SS
D 875 875 715 250 240 ABB_EHDB960C2P-1L2S ABB_EHDB960C-1L22SS
1K0 1050 858 300 240 SIEMENS-MFG_14-193-101-58-
2 (Qty 2)
SIEMENS-MFG_14-193-101-58-2 (Qty
1)
(1) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(2) Coil voltage = 115V AC, 50/60Hz.
(3) See DC Contactor Crimp Lug Kit Specifications on page 244
for more information.
(4) Wire and Lug size dependant on enclosure dimensions and local codes.
Frame
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Hp Dynamic Brake Resistor Kit
Cat. No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB
Resistor
Size
(Watts)
Brake Amps
Required
DC Loop Contactor Cat. No.
(2)
DC Contactor
Crimp Lugs
Cat. No.
(3)
Drive w/No Dynamic Brake Drive w Dynamic Brake
B 330 330 269.6 200 1370-DBH79 500 0.7 280 714.29 ABB_EHDB360C2P-1L2S ABB_EHDB360C-1L22SS
(4)
412 412 336.6 250 HUBBELL_Y95W808GB 500 0.808 7292 ABB_EHDB520C2P-1L2S ABB_EHDB520C-1L22SS
C 495 495 404.4 300 HUBBELL_Y101W595GB 500 0.595 6069 ABB_EHDB520C2P-1L2S ABB_EHDB520C-1L22SS
667 667 544.9 400 HUBBELL_Y109W542GB 500 0.542 6439 ABB_EHDB800C2P-1L2S ABB_EHDB800C-1L22SS
D 800 830 678.1 500
(1)
500 0.463 6338 ABB_EHDB960C2P-1L2S ABB_EHDB960C-1L22SS
960 996 813.7 600 500 0.322 6221 SIEMENS-MFG_14-193-101-58-2 (Qty
2)
SIEMENS-MFG_14-193-101-58-2
(Qty 1)
1K1 1162 949.4 700 500 0.322 6221 SIEMENS-MFG_14-193-101-58-2 (Qty
2)
SIEMENS-MFG_14-193-101-58-2
(Qty 1)
1K3 1328 1085.0 800 500 0.255 5718 CUTLER-HAMMER_6702ED636-2 (Qty
2)
CUTLER-HAMMER_6702ED636-2 (Qty
1)
1K4 1494 1220.6 900 500 0.255 5718 CUTLER-HAMMER_6702ED636-2 (Qty
2)
CUTLER-HAMMER_6702ED636-2 (Qty
1)
(1) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(2) Coil voltage = 115V AC, 50/60Hz.
(3) See DC Contactor Crimp Lug Kit Specifications on page 244
for more information.
(4) Wire and Lug size dependant on enclosure dimensions and local codes.