Owner's manual
Rockwell Automation Publication 20P-UM001I-EN-P - February 2013 243
Supplemental Drive Information Appendix A
Dynamic Brake Resistor Kits
and DC Output Contactors
See Table 83 on page 246 and Ta b le 8 4 on page 246 for recommended alternate
DC Output Contactors for 575V and 690V AC input drives, respectively.
Table 79 - 230V AC Input Drives
Table 80 - 460V AC Input Drives
Frame
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp Dynamic Brake
Resistor Kit Cat.
No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB Resistor
Size (Watts)
Brake Amps
Required
DC Loop
Contactor Cat.
No.
(3)
DC Contactor
Crimp Lugs Cat.
No.
(4)
A 7P0 7 5.7 1.5 1370-DBL62 240 20 420 12.00 1370-DC56 1370-LG40
9P0 9 7.4 2 1370-DBL63 240 20 420 12.00 1370-DC56 1370-LG40
012 12 9.8 3 1370-DBL64 240 15 420 16.00 1370-DC56 1370-LG40
020 20 16 5 1370-DBL65 240 8.6 420 27.91 1370-DC56 1370-LG40
029 29 24 7.5 1370-DBL66 240 6 345 40.00 1370-DC56 1370-LG40
038 38 31 10 1370-DBL67 240 5 330 48.00 1370-DC56 1370-LG40
055 55 45 15 1370-DBL68 240 3.5 385 68.57 1370-DC56 1370-LG56
073 73 60 20 1370-DBL69 240 2.6 385 92.31 1370-DC110 1370-LG92
093 93 76 25 1370-DBL70 240 2 330 120.00 1370-DC110 1370-LG92
110 110 90 30 1370-DBL71 240 2 330 120.00 1370-DC110 1370-LG110
B 146 146 119 40 1370-DBL72 240 0.7 280 342.86 1370-DC180 1370-LG160
180 180 147 50 1370-DBL73 240 0.5 365 480.00 1370-DC180 1370-LG180
218 218 178 60 1370-DBL74 240 0.5 365 480.00 1370-DC280 1370-LG228
265 265 217 75 1370-DBL75 240 2 330 120.00 1370-DC280 1370-LG268
360 360 294 100 1370-DBL76 240 1.4 290 171.43
(1) (5)
434 434 355 125
(1)
240 0.5 1458 651
(1) (5)
C 521 521 426 150
(1)
240 0.322 6221 781
(1) (5)
700 700 572 200
(2)
240 – – –
(1) (5)
D 875 875 715 250
(2)
240 – – –
(1) (5)
1K0 1050 858 300
(2)
240 – – –
(1) (5)
(1) See Alternate Dynamic Brake Resistor Kits and DC Output Contactors on page 245.
(2) No Dynamic Brake Resistor kit available for this drive rating - must be sourced locally.
(3) Coil voltage = 115V AC, 50/60Hz.
(4) See DC Contactor Crimp Lug Kit Specifications on page 244
for more information.
(5) Wire and Lug size dependant on enclosure dimensions and local codes.
Frame
Drive Current
Rating Code
DC
Amps
AC Line
Amps
Hp Dynamic Brake
Resistor Kit Cat.
No.
Armature
Voltage
(Volts)
DB Resistor
Size (ohms)
DB Resistor
Size (Watts)
Brake Amps
Required
DC Loop
Contactor Cat.
No.
(3)
DC Contactor
Crimp Lugs Cat.
No.
(4)
A 4P1 4.1 3.3 2 1370-DBH63 500 81 255 6.17 1370-DC56 1370-LG40
6P0 6 4.9 3 1370-DBH64 500 62 245 8.06 1370-DC56 1370-LG40
010 10 8.2 5 1370-DBH65 500 45 245 11.11 1370-DC56 1370-LG40
014 14 11.4 7.5 1370-DBH66 500 27 350 18.52 1370-DC56 1370-LG40
019 19 15.5 10 1370-DBH67 500 20 420 25.00 1370-DC56 1370-LG40
027 27 22.1 15 1370-DBH68 500 12 405 41.67 1370-DC56 1370-LG40
035 35 28.6 20 1370-DBH69 500 5 330 100.00 1370-DC56 1370-LG40
045 45 36.8 25 1370-DBH70 500 4.5 330 111.11 1370-DC56 1370-LG52
052 52 42.5 30 1370-DBH71 500 3.5 385 142.86 1370-DC56 1370-LG52
073 73 59.6 40 1370-DBH72 500 2.6 345 192.31 1370-DC110 1370-LG92
086 86 70.3 50 1370-DBH73 500 2 345 250.00 1370-DC110 1370-LG92
100 100 81.7 60 1370-DBH74 500 2 345 250.00 1370-DC110 1370-LG110
129 129 105.4 75 1370-DBH75 500 1 270 500.00 1370-DC180 1370-LG140
B 167 167 136.4 100 1370-DBH76 500 0.7 280 714.29 1370-DC180 1370-LG180
207 207 169.1 125 1370-DBH77 500 0.7 280 714.29 1370-DC280 1370-LG228
250 250 204.3 150 1370-DBH78 500 0.5 365 1000.00 1370-DC280 1370-LG268
330 330 269.6 200 1370-DBH79 500 0.7 280 714.29
(1) (5)
412 412 336.6 250
(1)
500 0.808 7292 –
(1) (5)
C 495 495 404.4 300
(1)
500 0.595 6069 –
(1) (5)
667 667 544.9 400
(1)
500 0.542 6439 –
(1) (5)