Instruction Manual

Publication 20P-IN061A-EN-P
8
10. Place the SCR leg assembly right side down on a work surface and
disconnect the wires from the connector mounted on the middle, left-side of
the assembly.
11. Remove the two hexalobular screws that secure the thermostat to the heat
sink and remove the thermostat.
Step 4: Install the New
Bimetal Thermostat
Install the new bimetal thermostat in the reverse order of removal as detailed in
Step 3: Remove the Existing Bimetal Thermostat
on page 4.
Important:Apply thermal grease to the bottom of the new bimetal thermostat
before installation.
Tightening torque for the bimetal thermostat is 1.0 N•m (8.9 lb•in).
Tightening torque for the SCR leg assembly is 4.5…5.0 N•m (40.0…44.4
lb•in).
Tightening torque for the SCR module input and output terminals to the fuse
terminals and DC output bus bars is 45 N•m (398 lb•in).