Manual

PowerFlex® DC Drive - Frame B SCR Modules 17
Step 6: Install the New
SCR Modules
Install the new SCR Modules in reverse order of removal as detailed in Step
5: Remove the Existing SCR Modules
on page 11.
Important Notes for installation:
Thermal grease must be applied to the bottom of each SCR Module
before securing it to the heatsink.
Use the following table to determine the proper tightening torque for the
SCR Modules installed on the heatsink:
Use the following orientation for installing the SCR Modules:
Use the following table to determine the proper tightening torque for the
bus bars connected to the SCR Modules:
230V AC Input 460V AC Input
Part Number Final Torque Part Number Final Torque
SK-20P-S7F48 2.5…4 N•m (22…35.4 lb•in) SK-20P-S7F78 2.5…4 N•m (22…35.4 lb•in)
SK-20P-S7F49 4.5…5.5 N•m (40…48.7 lb•in) SK-20P-S7F79 4.5…5.5 N•m (40…48.7 lb•in)
SK-20P-S7F42 4.5…5.5 N•m (40…48.7 lb•in) SK-20P-S7F41 4.5…5.5 N•m (40…48.7 lb•in)
SK-20P-S727F 4.5…5.5 N•m (40…48.7 lb•in) SK-20P-S737F 4.5…5.5 N•m (40…48.7 lb•in)
230V AC Input 460V AC Input
Part Number Final Torque Part Number Final Torque
SK-20P-S7F48 4.5…5.5 N•m (40…48.7 lb•in) SK-20P-S7F78 4.5…5.5 N•m (40…48.7 lb•in)
SK-20P-S7F49 4.5…5.5 N•m (40…48.7 lb•in) SK-20P-S7F79 4.5…5.5 N•m (40…48.7 lb•in)
SK-20P-S7F42 11…13 N•m (97.4…115 lb•in) SK-20P-S7F41 11…13 N•m (97.4…115 lb•in)
SK-20P-S727F 11…13 N•m (97.4…115 lb•in) SK-20P-S737F 11…13 N•m (97.4…115 lb•in)
1
2
3
2
1
3
Gate leads at top
Gate leads at bottom
This SCR Module
only present in
regenerative drives.