Parameter Cross Reference –
by Name
Parameter Name Number Group Page
Accel Mask 281 Masks & Owners 3-25
Accel Owner 293 Masks & Owners 3-26
Accel Time X 140, 141 Ramp Rates 3-15
Alarm Clear 261 Alarms 3-24
Alarm Config 1 259 Alarms 3-24
Alarm X @ Fault 229, 230 Diagnostics 3-23
Alarm X Code 262-269 Alarms 3-24
Analog In X Hi 322, 325 Analog Inputs 3-28
Analog In X Lo 323, 326 Analog Inputs 3-28
Analog In X Loss 324, 327 Analog Inputs 3-28
Analog In1 Value 16 Metering 3-6
Analog In2 Value 17 Metering 3-6
Analog OutX Hi 343 Analog Outputs 3-29
Analog OutX Lo 344 Analog Outputs 3-29
Analog OutX Sel 342 Analog Outputs 3-29
Anlg In Config 320 Analog Inputs 3-28
Anlg In Sqr Root 321 Analog Inputs 3-28
Anlg Out Absolut 341 Analog Outputs 3-29
Anlg Out Config 340 Analog Outputs 3-28
Auto Rstrt Delay 175 Restart Modes 3-16
Auto Rstrt Tries 174 Restart Modes 3-16
Autotune 61 Torq Attributes 3-8
Break Frequency 72 Volts per Hertz 3-9
Break Voltage 71 Volts per Hertz 3-9
Bus Reg Kd 165 Stop/Brake Modes 3-16
Bus Reg Ki 160 Stop/Brake Modes 3-15
Bus Reg Kp 164 Stop/Brake Modes 3-16
Bus Reg Mode X 161, 162 Stop/Brake Modes 3-16
Commanded Freq 2 Metering 3-6
Commanded Speed 2 Metering 3-6
Compensation 56 Torq Attributes 3-7
Control SW Ver 29 Drive Data 3-6
Current Lmt Gain 149 Load Limits 3-15
Current Lmt Sel 147 Load Limits 3-15
Current Lmt Val 148 Load Limits 3-15
Data In XX 300-307 Datalinks 3-27
Data Out XX 310-317 Datalinks 3-27
DB Resistor Type 163 Stop/Brake Modes 3-16
DC Brake Level 158 Stop/Brake Modes 3-15
DC Brake Time 159 Stop/Brake Modes 3-15
DC Brk Lvl Sel 157 Stop/Brake Modes 3-15
DC Bus Memory 13 Metering 3-6
DC Bus Voltage 12 Metering 3-6
Decel Mask 282 Masks & Owners 3-25
Decel Owner 294 Masks & Owners 3-26
Decel Time X 142, 143 Ramp Rates 3-15
Dig In Status 216 Diagnostics 3-22
Dig Out Status 217 Diagnostics 3-22
Dig OutX Level 381, 385 Digital Outputs 3-31
Dig OutX OffTime 383, 387 Digital Outputs 3-31
Dig OutX OnTime 382, 386 Digital Outputs 3-31
Digital InX Sel 361-366 Digital Inputs 3-30
Digital OutX Sel 380, 384 Digital Outputs 3-31
Direction Mask 279 Masks & Owners 3-25
Direction Mode 190 Direction Config 3-19
Direction Owner 291 Masks & Owners 3-26
DPI Baud Rate 270 Comm Control 3-25
DPI Data Rate 270 Comm Control 3-25
Drive Alarm X 211, 212 Diagnostics 3-21
Drive Checksum 203 Drive Memory 3-20
Drive Logic Rslt 271 Comm Control 3-25
Drive OL Count 219 Diagnostics 3-22
Drive OL Mode 150 Load Limits 3-15
Drive Ramp Rslt 273 Comm Control 3-25
Drive Ref Rslt 272 Comm Control 3-25
Drive Status X 209, 210 Diagnostics 3-20
Drive Temp 218 Diagnostics 3-22
Elapsed MWh 9 Metering 3-6
Elapsed Run Time 10 Metering 3-6
Fault 1 Code 243 Faults 3-24
Fault 1 Time 244 Faults 3-24
Fault 2 Code 245 Faults 3-24
Fault 2 Time 246 Faults 3-24
Fault 3 Code 247 Faults 3-24
Fault 3 Time 248 Faults 3-24
Fault 4 Code 249 Faults 3-24
Fault 4 Time 250 Faults 3-24
Fault 5 Code 251 Faults 3-24
Fault 5 Time 252 Faults 3-24
Fault 6 Code 253 Faults 3-24
Fault 6 Time 254 Faults 3-24
Fault 7 Code 255 Faults 3-24
Fault 7 Time 256 Faults 3-24
Fault 8 Code 257 Faults 3-24
Fault 8 Time 258 Faults 3-24
Fault Amps 225 Diagnostics 3-22
Fault Bus Volts 226 Diagnostics 3-22
Fault Clear 240 Faults 3-23
Fault Clear Mode 241 Faults 3-23
Fault Clr Mask 283 Masks & Owners 3-26
Fault Clr Owner 295 Masks & Owners 3-26
Fault Config 1 238 Faults 3-23
Fault Frequency 224 Diagnostics 3-22
Fault Speed 224 Diagnostics 3-22
Feedback Select 80 Spd Mode & Limits 3-10
Flux Current 5 Metering 3-6
Flux Current Ref 63 Torq Attributes 3-8
Flux Up Mode 57 Torq Attributes 3-8
Flux Up Time 58 Torq Attributes 3-8
Flying Start En 169 Restart Modes 3-16
Flying StartGain 170 Restart Modes 3-16
IR Voltage Drop 62 Torq Attributes 3-8
Ixo Voltage Drop 64 Torq Attributes 3-8
Jog Mask 278 Masks & Owners 3-25
Jog Owner 290 Masks & Owners 3-26
Jog Speed 100 Discrete Speeds 3-12
Jog Speed 1 100 Discrete Speeds 3-12
Language 201 Drive Memory 3-20
Last Stop Source 215 Diagnostics 3-21
Load Frm Usr Set 198 Drive Memory 3-19
Local Mask 285 Masks & Owners 3-26
Local Owner 297 Masks & Owners 3-26
Logic Mask 276 Masks & Owners 3-25
Man Ref Preload 193 HIM Ref Config 3-19
Maximum Freq 55 Torq Attributes 3-7
Maximum Speed 82 Spd Mode & Limits 3-10
Maximum Voltage 54 Torq Attributes 3-7
Minimum Speed 81 Spd Mode & Limits 3-10
MOP Frequency 11 Metering 3-6
MOP Mask 284 Masks & Owners 3-26
MOP Owner 296 Masks & Owners 3-26
MOP Rate 195 MOP Config 3-19
MOP Reference 11 Metering 3-6
Motor Cntl Sel 53 Torq Attributes 3-7
Motor NP FLA 42 Motor Data 3-7
Motor NP Hertz 43 Motor Data 3-7
Motor NP Power 45 Motor Data 3-7
Motor NP RPM 44 Motor Data 3-7
Motor NP Volts 41 Motor Data 3-7
Motor OL Count 220 Diagnostics 3-22
Motor OL Factor 48 Motor Data 3-7
Motor OL Hertz 47 Motor Data 3-7
Motor Type 40 Motor Data 3-7
Mtr NP Pwr Units 46 Motor Data 3-7
Output Current 3 Metering 3-6
Output Freq 1 Metering 3-6
Output Power 7 Metering 3-6
Output Powr Fctr 8 Metering 3-6
Output Voltage 6 Metering 3-6
Overspeed Limit 83 Spd Mode & Limits 3-10
Param Access Lvl 196 Drive Memory 3-19
PI Configuration 124 Process PI 3-13
PI Control 125 Process PI 3-13
PI Error Meter 137 Process PI 3-14
PI Fdback Meter 136 Process PI 3-14
PI Feedback Sel 128 Process PI 3-13
PI Integral Time 129 Process PI 3-13
PI Lower Limit 131 Process PI 3-13
PI Output Meter 138 Process PI 3-14
Parameter Name Number Group Page
PI Preload 133 Process PI 3-14
PI Prop Gain 130 Process PI 3-13
PI Ref Meter 135 Process PI 3-14
PI Reference Sel 126 Process PI 3-13
PI Setpoint 127 Process PI 3-13
PI Status 134 Process PI 3-14
PI Upper Limit 132 Process PI 3-13
Power Loss Level 186 Power Loss 3-18
Power Loss Mode 184 Power Loss 3-18
Power Loss Time 185 Power Loss 3-18
Power Up Marker 242 Faults 3-23
Preset Speed X 101-107 Discrete Speeds 3-12
PWM Frequency 151 Load Limits 3-15
Rated Amps 28 Drive Data 3-6
Rated kW 26 Drive Data 3-6
Rated Volts 27 Drive Data 3-6
Reference Mask 280 Masks & Owners 3-25
Reference Owner 292 Masks & Owners 3-26
Reset Meters 200 Drive Memory 3-20
Reset To Defalts 197 Drive Memory 3-19
Run Boost 70 Volts per Hertz 3-9
S Curve % 146 Ramp Rates 3-15
Save HIM Ref 192 HIM Ref Config 3-19
Save MOP Ref 194 MOP Config 3-19
Save To User Set 199 Drive Memory 3-19
Skip Freq Band 87 Spd Mode & Limits 3-10
Skip Frequency X 84-86 Spd Mode & Limits 3-10
Sleep Level 182 Restart Modes 3-17
Sleep Time 183 Restart Modes 3-17
Sleep-Wake Mode 178 Restart Modes 3-17
Sleep-Wake Ref 179 Restart Modes 3-17
Slip Comp Gain 122 Slip Comp 3-12
Slip RPM @ FLA 121 Slip Comp 3-12
Slip RPM Meter123 Slip Comp 3-12
Speed Mode 80 Spd Mode & Limits 3-10
Speed Ref Source 213 Diagnostics 3-21
Speed Ref X Hi 91, 94 Speed Reference 3-11
Speed Ref X Lo 92, 95 Speed Reference 3-11
Speed Ref X Sel 90, 93 Speed Reference 3-11
Start At PowerUp 168 Restart Modes 3-16
Start Inhibits 214 Diagnostics 3-21
Start Mask 277 Masks & Owners 3-25
Start Owner 289 Masks & Owners 3-26
Start/Acc Boost 69 Volts per Hertz 3-9
Status X @ Fault 227, 228 Diagnostics 3-22
Stop Mode X 155, 156 Stop/Brake Modes 3-15
Stop Owner 288 Masks & Owners 3-26
Stop/BRK Mode X 155, 156 Stop/Brake Modes 3-15
SV Boost Filter 59 Torq Attributes 3-8
TB Man Ref Hi 97 Speed Reference 3-11
TB Man Ref Lo 98 Speed Reference 3-11
TB Man Ref Sel 96 Speed Reference 3-11
Testpoint X Data 235, 237 Diagnostics 3-23
Testpoint X Sel 234, 236 Diagnostics 3-23
Torque Current 4 Metering 3-6
Torque Perf Mode 53 Torq Attributes 3-7
Trim Hi 119 Speed Trim 3-12
Trim In Select 117 Speed Trim 3-12
Trim Lo 120 Speed Trim 3-12
Trim Out Select 118 Speed Trim 3-12
Voltage Class 202 Drive Memory 3-20
Wake Level 180 Restart Modes 3-17
Wake Time 181 Restart Modes 3-17