Instruction Manual

Programming and Parameters 3-29
INPUTS & OUTPUTS
Analog Outputs
341 [Anlg Out Absolut]
Selects whether the signed value or absolute value of a parameter is used before being scaled to drive the analog
output.
342 [Analog Out1 Sel]
Selects the source of the value that drives the analog output.
Default:
Options:
0 “Output Freq”
See Table
001, 002,
003
, 004,
005
, 006,
007
, 012,
135
, 136,
137
, 138,
220
, 219
343 [Analog Out1 Hi]
Sets the analog output value when the source value is at maximum.
Default:
Min/Max:
Units:
20.000 mA, 10.000 Volts
4.000/20.000mA
–/+10.000V
0.000/10.000V
0.001 mA
0.001 Volt
340, 342
344 [Analog Out1 Lo]
Sets the analog output value when the source value is at minimum.
Default:
Min/Max:
Units:
0.000 mA, 0.000 Volts
4.000/20.000mA
–/+10.000V
0.000/10.000V
0.001 mA
0.001 Volt
340, 342
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values Related
xxx 1xxxxxxxxxxxx
10 01234567891112131415
1 =Absolute
0 =Signed
x =Reserved
Bit #
Factory Default Bit Values
Analog Out1
Options
[Analog Out1 Lo] Value
[Analog Out1 Hi] Value
Param. 341 = Signed Param. 341 = Absolute
0
1
2
3
4
5
6
7
8
9
10
11
12
13
“Output Freq”
“Command Freq”
“Output Amps”
“Torque Amps”
“Flux Amps”
“Output Power”
“Output Volts”
“DC Bus Volts”
“PI Reference”
“PI Feedback”
“PI Error”
“PI Output”
“%Motor OL
“%Drive OL
–[Maximum Speed]
–[Maximum Speed]
0 Amps
–200% Rated
0 Amps
0 kW
0 Volts
0 Volts
–100%
–100%
–100%
–100%
0%
0%
0 Hz
0 Hz
0 Amps
0 Amps
0 Amps
0 kW
0 Volts
0 Volts
0%
0%
0%
0%
0%
0%
+[Maximum Speed]
+[Maximum Speed]
200% Rated
200% Rated
200% Rated
200% Rated
120% Rated Input Volts
200% Rated Input Volts
100%
100%
100%
100%
100%
100%