Instruction Manual
3-6 Programming and Parameters
Monitor File
File
Group
No.
Parameter Name & Description
See page 3-2 for symbol descriptions
Values Related
MONITOR
Metering
001 [Output Freq]
Output frequency present at T1, T2 & T3 (U, V & W).
Default:
Min/Max:
Units:
Read Only
–/+[Maximum Freq]
0.1 Hz
002 [Commanded Freq]
Value of the active frequency command.
Default:
Min/Max:
Units:
Read Only
–/+[Maximum Speed]
0.1 Hz
003 [Output Current]
The total output current present at T1, T2 & T3 (U, V & W).
Default:
Min/Max:
Units:
Read Only
0.0/Drive Rated Amps × 2
0.1 Amps
004 [Torque Current]
Based on the motor, the amount of current that is in phase with the
fundamental voltage component.
Default:
Min/Max:
Units:
Read Only
Drive Rating × –2/+2
0.1 Amps
005 [Flux Current]
Amount of current that is out of phase with the fundamental voltage
component.
Default:
Min/Max:
Units:
Read Only
Drive Rating × –2/+2
0.1 Amps
006 [Output Voltage]
Output voltage present at terminals T1, T2 & T3 (U, V & W).
Default:
Min/Max:
Units:
Read Only
0.0/Drive Rated Volts
0.1 VAC
007 [Output Power]
Output power present at T1, T2 & T3 (U, V & W).
Default:
Min/Max:
Units:
Read Only
0.0/Drive Rated kW × 2
0.1 kW
008 [Output Powr Fctr]
Output power factor.
Default:
Min/Max:
Units:
Read Only
0.00/1.00
0.01
009 [Elapsed MWh]
Accumulated output energy of the drive.
Default:
Min/Max:
Units:
Read Only
0.0/214748364.0 MWh
0.1 MWh
010 [Elapsed Run Time]
Accumulated time drive is outputting power.
Default:
Min/Max:
Units:
Read Only
0.0/429496729.5 Hrs
0.1 Hrs
011 [MOP Frequency]
Value of the signal at MOP (Motor Operated Potentiometer).
Default:
Min/Max:
Units:
Read Only
–/+[Maximum Freq]
0.1 Hz
012 [DC Bus Voltage]
Present DC bus voltage level.
Default:
Min/Max:
Units:
Read Only
0.0/Based on Drive Rating
0.1 VDC
013 [DC Bus Memory]
6 minute average of DC bus voltage level.
Default:
Min/Max:
Units:
Read Only
0.0/Based on Drive Rating
0.1 VDC
016
017
[Analog In1 Value]
[Analog In2 Value]
Value of the signal at the analog inputs.
Default:
Min/Max:
Units:
Read Only
0.000/20.000 mA
–/+10.000V
0.001 mA
0.001 Volt
Drive Data
026 [Rated kW]
Drive power rating.
Default:
Min/Max:
Units:
Read Only
0.00/3000.00 kW
0.01 kW
027 [Rated Volts]
The drive input voltage class (208, 240, 400, etc.).
Default:
Min/Max:
Units:
Read Only
0.0/6553.5 VAC
0.1 VAC
028 [Rated Amps]
The drive rated output current.
Default:
Min/Max:
Units:
Read Only
0.0/6553.5 Amps
0.1 Amps
029 [Control SW Ver]
Main Control Board software version.
Default:
Min/Max:
Units:
Read Only
0.000/256.256
0.001