Installation Instructions Owner's manual

58 Rockwell Automation Publication 20D-IN024C-EN-P - July 2013
PowerFlex 700S Adjustable Frequency AC Drive - Phase II Control
Primary Encoder Interface
Supports 5V DC or 12V DC differential encoders
with internal power supply.
Used as primary closed loop feedback.
Internal Supply Using Encoder 0 as speed feedback:
Par 222 [Mtr Fdbk Sel Pri] = 0 “Encoder 0” (default)
Par 232 [Encoder0 PPR] = Pulses/Rev for installed encoder
External Supply
Input/Output Connection Example Required Parameter Changes
A-
A
Encoder
13
14
15
16
17
18
19
20
21
22
23
24
B-
B
Z-
Z
-
+
Power +V
Common -V
Shield
A-
A
Encoder
13
14
15
16
17
18
19
20
21
22
23
24
B-
B
Z-
Z
-
+