22 Rockwell Automation Publication 20D-IN024C-EN-P - July 2013
PowerFlex 700S Adjustable Frequency AC Drive - Phase II Control
Step 3: Lift and Mount the
Drive
Drive Weights
Table 9 - Approximate Drive Weights
Attaching the Lifting Hardware
All lifting equipment and lifting components (hooks, bolts, lifts, slings, chains,
and so forth) must be properly sized and rated to safely lift and hold the weight of
the drive while mounting. See Figure 8
and Figure 9 on page 23, and Figure 10 on
page 24
for lifting instructions.
Frame Size Drive Rating Drive Weight
(1)
(1) Weights include HIM, DriveLogix controller with ControlNet daughtercard, Hi-Resolution Encoder Option, and 20-COMM-C
ControlNet adapter.
kW Hp kg (lb)
1 0.75…11 1…10 7.0 (15.5)
2 7.5…18.5 10…25 12.5 (27.6)
3 11…37 15…50 18.6 (40.9)
4 25…60 18.5…55 24.5 (54.0)
5 40…100 30…90 37.2 (82.0)
6 60…200 45…132 71.5 (157.5)
(2)
(2) Add an additional 3.6 kg (8.0 lb) for 200 Hp drives.
ATTENTION: To guard against possible personal injury and/or equipment
damage…
• Inspect all lifting hardware for proper attachment before lifting drive.
• Do not allow any part of the drive or lifting mechanism to make contact with
electrically charged conductors or components.
• Do not subject the drive to high rates of acceleration or deceleration while
transporting to the mounting location or when lifting.
• Do not allow personnel or their limbs directly underneath the drive when it is
being lifted and mounted.