Owner's manual

3-64 Programming and Parameters
No.
Name
Description Values
Linkable
Read-Write
Data Type
623 Real In11
Displays input word 11 of the controller communication format in floating point format.
Paired with Par 622 [Integer In11], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
624 Integer In12
Displays input word 12 of the controller communication format in integer format. Paired
with Par 625 [Real In12], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
625 Real In12
Displays input word 12 of the controller communication format in floating point format.
Paired with Par 624 [Integer In12], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
626 Integer In13
Displays input word 13 of the controller communication format in integer format. Paired
with Par 627 [Real In13], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
627 Real In13
Displays input word 13 of the controller communication format in floating point format.
Paired with Par 626 [Integer In13], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
628 Integer In14
Displays input word 14 of the controller communication format in integer format. Paired
with Par 629 [Real In14], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
629 Real In14
Displays input word 14 of the controller communication format in floating point format.
Paired with Par 628 [Integer In14], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
630 Integer In15
Displays input word 15 of the controller communication format in integer format. Paired
with Par 631 [Real In15], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
32-bit
Integer
631 Real In15
Displays input word 15 of the controller communication format in floating point format.
Paired with Par 630 [Integer In15], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
Real
632 Integer Out00
Displays output word 00 of the controller communication format in integer format. Paired
with Par 633 [Real Out00], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
633 Real Out00
Displays output word 00 of the controller communication format in floating point format.
Paired with Par 632 [Integer Out00], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
634 Integer Out01
Displays output word 01 of the controller communication format in integer format. Paired
with Par 635 [Real Out01], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
635 Real Out01
Displays output word 01 of the controller communication format in floating point format.
Paired with Par 634 [Integer Out01], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
636 Integer Out02
Displays output word 02 of the controller communication format in integer format. Paired
with Par 637 [Real Out02], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
637 Real Out02
Displays output word 02 of the controller communication format in floating point format.
Paired with Par 636 [Integer Out02], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
638 Integer Out03
Displays output word 03 of the controller communication format in integer format. Paired
with Par 639 [Real Out03], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
639 Real Out03
Displays output word 03 of the controller communication format in floating point format.
Paired with Par 638 [Integer Out03], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
640 Integer Out04
Displays output word 04 of the controller communication format in integer format. Paired
with Par 641 [Real Out04], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
641 Real Out04
Displays output word 04 of the controller communication format in floating point format.
Paired with Par 640 [Integer Out04], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
642 Integer Out05
Displays output word 05 of the controller communication format in integer format. Paired
with Par 643 [Real Out05], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer
643 Real Out05
Displays output word 05 of the controller communication format in floating point format.
Paired with Par 642 [Integer Out05], which displays the same data in integer format.
Default:
Min/Max:
0.0000
-/+2200000000.0000
✓✓Real
644 Integer Out06
Displays output word 06 of the controller communication format in integer format. Paired
with Par 645 [Real Out06], which displays the same data in floating point format.
Default:
Min/Max:
0
-/+2147483648
✓✓32-bit
Integer