User guide
Publication PFLEX-IN023A-EN-P
38
26. Remove the M10 bolts and washers that secure the AC input supply cables
and SCR terminal bus bars to the rectifier module and remove the cables
and bus bars from the rectifier module.
27. Remove the six M10x20 bolts and washers that secure the DC- and DC+
rectifier bus bars to the rectifier module and remove the bus bars.
Important: Do Not
reuse the existing DC+ rectifier bus bar.
Remove bolts
17 mm
12 N•m
(106 lb•in)
AC supply cables
Terminal bus bars
Remove bolts
17 mm
12 N•m
(106 lb•in)
Do Not reuse existing DC+ bus bar