User guide
17
Publication PFLEX-IN023A-EN-P
7. Remove the six M10x20 bolts and washers that secure the DC- and DC+
rectifier bus bars and power cable to the SCRs on the rectifier module and
remove the bus bars and power cable.
Important: Do Not
reuse the existing DC+ rectifier bus bar.
Remove bolts
17 mm
14 N•m
(124 lb•in)
Remove bolts
Do Not reuse existing DC+ bus bar
Top of Power
Structure
Power cable