PowerFlex 700 Adjustable Frequency AC Drive – Frames 7…10
•Assisted Start Up
Three levels of Assisted Start Up (Basic, Detailed and Application) aid the
user in commissioning the drive asking simple Yes/No or “Enter Data
questions. The user is guided through the Start Up to reduce the amount
of time necessary to get the drive “up and running.” The following are
included in startup:
Input Voltage Ratings
Motor Data
Motor Tests & Auto-tuning
Speed/Torque Control & Direction Limits
Speed Reference
Start & Stop Modes
Ramp Setup
Digital and Analog I/O
Application Set-up (TorqProve, Oil Well Pumps, Positioning/Speed
Profiling)
See page 67
for details.
IMPORTANT
Power must be applied to the drive when viewing or changing parameters.
Previous programming can affect the drive status and operation when power is
applied. If the I/O Cassette has been changed, a Reset Defaults operation must
be performed.
Torque Proving applications can use the Assisted Start Up to tune the motor.
However, it is recommended that the motor be disconnected from the hoist/
crane equipment during the routine. If this is not possible, refer to the manual
tuning procedure in the User Manual.