Installation Instructions - Frames 7…10 User Manual

12 Rockwell Automation Publication 20B-IN014H-EN-P - June 2013
PowerFlex 700 Adjustable Frequency AC Drive – Frames 7…10
Step 2: Lifting and Mounting
the Drive
Lifting
Frame 7
ATTENTION: To guard against possible personal injury and/or equipment
damage:
Do Not allow any part of the drive or lifting mechanism to make contact with
electrically charged conductors or components.
At no time should a person or their limbs be directly underneath the items
being lifted.
Do not subject the load to high rates of acceleration or deceleration.
Inspect all lifting hardware for proper attachment before lifting drive unit.
IMPORTANT
Braces attached to the front of Frame 8, 9 or 10 IP20, NEMA/UL Type 1 drives
are required for structural integrity. If necessary, the braces can be removed for
wiring, but must be replaced upon completion.
IP00, NEMA/UL Type Open
Approximate Weight 147 kg (324 lbs.) + 26 kg (58 lbs.) for shipping materials
IP20, NEMA/UL Type 1
Approximate Weight 170 kg (375 lbs.) + 26 kg (58 lbs.) for shipping materials
>
1
/
2 A
A
45°
Lifting Holes
4 Places