Manual
Table Of Contents
- PowerFlex 700H Adjustable Frequency AC Drive Programming Manual
- Summary of Changes
- Table of Contents
- Preface
- 1 - Drive Start-Up
- 2 - Programming and Parameters
- 3 - Troubleshooting
- Drive Status
- Faults and Alarms
- Manually Clear Faults
- Fault and Alarm Descriptions
- Fault Subcodes
- Clear Alarms
- Common Drive Symptoms and Corrective Actions
- Drive does not Start from Start or Run Inputs Wired to the Terminal Block
- Drive does not Start from HIM
- Drive does not Respond to Changes in Speed Command
- Motor and/or Drive will not Accelerate to Commanded Speed
- Motor Operation is Unstable
- Drive will not Reverse Motor Direction
- Stopping the Drive Results in a Decel Inhibit Fault
- Technical Support Options
- A - HIM Overview
- B - Application Notes
- C - History of Changes
- Index
- Back Cover

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 43
Programming and Parameters Chapter 2
UTILITY
Faults
243
245
247
249
251
253
255
257
[Fault 1 Code]
[Fault 2 Code]
[Fault 3 Code]
[Fault 4 Code]
[Fault 5 Code]
[Fault 6 Code]
[Fault 7 Code]
[Fault 8 Code]
A code that represents the fault that tripped the
drive. The codes will appear in these parameters
in the order they occur ([Fault 1 Code] = the most
recent fault). See Fault and Alarm Descriptions
on
page 64 for a list of fault and alarm codes and the
corresponding descriptions and possible actions.
Default:
Min/Max:
Units:
Read Only
0/65535
0
244
246
248
250
252
254
256
258
[Fault 1 Time]
[Fault 2 Time]
[Fault 3 Time]
[Fault 4 Time]
[Fault 5 Time]
[Fault 6 Time]
[Fault 7 Time]
[Fault 8 Time]
The time between initial drive power up and the
occurrence of the associated trip fault. Can be
compared to [Power Up Marker] for the time from
the most recent power up.
[Fault x Time] – [Power Up Marker] = Time
difference to the most recent power up. A
negative value indicates fault occurred before
most recent power up. A positive value indicates
fault occurred after most recent power up.
Default:
Min/Max:
Units:
Read Only
0.0000/429496.7295 Hr
0.0001 Hr
242
543
545
547
549
551
553
555
557
[Fault 1 Subcode]
[Fault 2 Subcode]
[Fault 3 Subcode]
[Fault 4 Subcode]
[Fault 5 Subcode]
[Fault 6 Subcode]
[Fault 7 Subcode]
[Fault 8 Subcode]
Fault subcode. Provides additional information for
certain faults. Refer to Fault and Alarm
Descriptions on page 64.
Note: Added for firmware revision 4.001.
Default:
Min/Max:
Units:
Read Only
0/65535
1
File
Group
No.
Parameter Name & Description Values
Related
32