284 [MOP Mask]
Controls which adapters can issue MOP
commands to the drive.
See [Logic Mask]
. 288
297
285 [Local Mask]
Controls which adapters are allowed to take
exclusive control of drive logic commands (except
stop). Exclusive “local” control can only be taken
while the drive is stopped.
See [Logic Mask]. 288
297
288 [Stop Owner]
Adapters that are presently issuing a valid stop command.
Read Only 276
285
289 [Start Owner]
Adapters that are presently issuing a valid start
command.
See [Stop Owner]. 276
285
290 [Jog Owner]
Adapters that are presently issuing a valid jog
command.
See [Stop Owner]
. 276
285
291 [Direction Owner]
Adapter that currently has exclusive control of
direction changes.
See [Stop Owner]. 276
285
292 [Reference Owner]
Adapter that has the exclusive control of the
command frequency source selection.
See [Stop Owner]. 276
285
293 [Accel Owner]
Adapter that has exclusive control of selecting
[Accel Time 1, 2].
See [Stop Owner]
. 140
276
285
294 [Decel Owner]
Adapter that has exclusive control of selecting
[Decel Time 1, 2].
See [Stop Owner]
. 142
276
285
295 [Fault Clr Owner]
Adapter that is presently clearing a fault.
See [Stop Owner]. 276
285
296 [MOP Owner]
Adapters that are currently issuing increases or
decreases in MOP command frequency.
See [Stop Owner]. 276
285
297 [Local Owner]
Adapter that has requested exclusive control of
all drive logic functions. If an adapter is in local
lockout, all other functions (except stop) on all
other adapters are locked out and non-
functional. Local control can only be obtained
when the drive is not running.
See [Stop Owner]
. 276
285
File
Group
No.
Parameter Name & Description
See page 16 for symbol descriptions
Values
Related
000100xxxxxxxxxx
10 01234567891112131415
1 = Issuing Command
0 = No Command
x = Reserved
Bit #
Digital In
DPI Port 1
DPI Port 2
DPI Port 3
DPI Port 4
DPI Port 5