User guide
Publication 2099-QR003A-EN-P — October 2008 328028-P02
Supersedes Publication 2099-PA001A-EN-P — May 2006 Copyright © 2008 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
Kinetix is a trademark of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
Quick Reference
Remove Jumpers in Kinetix 7000 Drives
Catalog Numbers 2099-BM06-S, 2099-BM07-S, 2099-BM08-S,
2099-BM09-S, 2099-BM10-S, 2099-BM11-S, 2099-BM12-S
This document provides information regarding the protective metal oxide
varistors (MOVs) and common mode capacitors in the Kinetix 7000 drives.
The MOVs, capacitors, and a sticker describing this issue
, are located within
the power terminal block. Refer to the Kinetix 7000 High Power Servo Drives
Installation Instructions, publication
2099-IN003, for more information.
ATTENTION
Kinetix 7000 drives contain protective MOVs and common mode
capacitors that are referenced to ground. In a grounded power
distribution system, these devices assist in isolating the drive
from electromagnetic interference (EMI).
These devices must be disconnected if the drive is installed in:
• unbalanced, ungrounded, or resistive-grounded power
di
stribution systems.
• common bus configurations.