Design Guide

Rockwell Automation Publication GMC-RM008A-EN-P - September 2011 67
Ultra3000 Drive Systems
LDC-Series Performance Specifications with Ultra3000 (400V class) Drives (continued)
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Linear Motor
Speed, max
m/s (ft/s)
System Continuous
Stall Current
(1)
Amps 0-pk
(1) Values represent the range between no cooling (low value) and water cooling (high value).
System Continuous
Stall Force
(1)
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Linear Motor
Rated Output
kW
Ultra3000
400V-class Drives
LDC-C075200-DHT
10.0 (32.8)
7.7…11.5
348…523
(78…117)
22.9
882 (198) 1.74…2.61
2098-DSD-HV100
LDC-C075200-EHT 3.8…5.7 11.5 2098-DSD-HV030
LDC-C075300-DHT 11.5…17.2
523…784
(117…176)
35.6
1368 (308) 2.61…3.92
2098-DSD-HV100
LDC-C075300-EHT 3.8…5.7 11.9 2098-DSD-HV030
LDC-C075400-DHT 15.3…23.0
697…1045
(157…235)
47.4
1824 (410) 3.48…5.22
2098-DSD-HV150
LDC-C075400-EHT 7.7…11.5 23.7 2098-DSD-HV100
LDC-C100300-DHT
10.0 (32.8)
11.1…16.7
674…1012
(152…227)
34.3
1767 (397) 3.37…5.06
2098-DSD-HV100
LDC-C100300-EHT 3.7…5.6 11.4 2098-DSD-HV030
LDC-C100400-DHT 14.8…22.2
899…1349
(202…303)
45.7
2356 (530) 4.49…6.74
2098-DSD-HV150
LDC-C100400-EHT 7.4…11.1 22.8 2098-DSD-HV100
LDC-C100600-DHT 22.2…33.3
1349…2023
(303…455)
68.5
3534 (794) 6.74…10.11
2098-DSD-HV220
LDC-C100600-EHT 11.1…16.7 34.3 2098-DSD-HV100
LDC-C150400-DHT
10.0 (32.8)
14.1…21.1
1281…1922
(288…432)
45.2
3498 (786) 6.40…9.61
2098-DSD-HV150
LDC-C150400-EHT 7.0…10.6 22.6 2098-DSD-HV100
LDC-C150600-DHT 21.1…31.7
1922…2882
(432…648)
67.8
5246 (1179) 9.61…14.41
2098-DSD-HV220
LDC-C150600-EHT 10.6…15.8 33.9 2098-DSD-HV100