Design Guide
Rockwell Automation Publication GMC-RM008A-EN-P - September 2011 43
Ultra3000 Drive Systems
Bulletin TLY (brake) Performance Specifications with Ultra3000 (200V class) Drives
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Ultra3000 (200V class) Drives/TLY-Axxxx-H (incremental) Motor Curves
Rotary Motor
Speed, max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Torque
N•m (lb•in)
Motor Rated
Output
kW
Ultra3000
200V-class Drives
TLY-A110T
6000
0.50 0.086 (0.76) 1.50 0.20 (1.75) 0.037 2098-DSD-005
TLY-A120T 0.93 0.163 (1.44) 2.50 0.36 (3.20) 0.077 2098-DSD-005
TLY-A130T 1.67 0.293 (2.59) 4.90 0.76 (6.70) 0.13 2098-DSD-005
TLY-A220T
2.50 0.576 (5.10) 7.50 1.40 (12.4)
0.24
2098-DSD-005
3.15 0.757 (6.70) 7.90 1.48 (13.1) 2098-DSD-010
TLY-A230T 4.95 1.16 (10.3)
15.0 2.94 (26.0)
0.32
2098-DSD-010
15.5 3.05 (27.0) 2098-DSD-020
TLY-A2530P
5000
5.00 1.32 (11.7) 15.0 3.73 (33.0)
0.55
2098-DSD-010
10.0 2.60 (23.0) 21.0 5.20 (46.0) 2098-DSD-020
TLY-A2540P
5.0 1.49 (13.2) 15.0 4.40 (39.0)
0.66
2098-DSD-010
10.0 2.94 (26.0) 24.8 7.10 (63.0) 2098-DSD-020
TLY-A310M 4500 10.0 3.61 (31.9) 30.0 9.0 (79.6) 0.90 2098-DSD-020
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2098-DSD-005 and TLY-A110T-H
0
3000
5000
0.250
0.200
0.150
0.100
0.050
0
40001000
2000
2.21
1.77
1.33
0.88
0.44
0
6000
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2098-DSD-005 and TLY-A110T-H (Brake)
0.250
0.200
0.150
0.100
0.050
0
2.21
1.77
1.33
0.88
0.44
0
0
3000
5000
40001000
2000
6000
= Intermittent operating region
= Continuous operating region