Design Guide
28 Rockwell Automation Publication GMC-RM008A-EN-P - September 2011
Ultra3000 Drive Systems
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.
Ultra3000 (400V class) Drives/MP-Series Medium Inertia Motor Curves
MPM-B1653E 2250 3500 27.00 26.8 (237)
68.0 58.8 (520)
5.10
2098-DSD-HV150
72.9 62.0 (549) 2098-DSD-HV220
MPM-B1653F 3000 4000 34.94 31.0 (274) 94.0 56.1 (496) 5.10 2098-DSD-HV220
MPM-B2152C 1500 2500 27.40 36.7 (325) 55.4 72.2 (639) 5.60 2098-DSD-HV150
MPM-B2152F 3000 4500 43.54 33.9 (300) 94.0 69.8 (618) 5.90 2098-DSD-HV220
MPM-B2152M 4500 5000 44.58 34.1 (302) 94.0 52.9 (468) 5.90 2098-DSD-HV220
MPM-B2153B 1250 2000 24.06
47.1 (417) 46.0 81.5 (721)
6.80
2098-DSD-HV100
48.0 (425) 60.0 101.2 (895) 2098-DSD-HV150
MPM-B2153E 2250 3000 39.63 47.9 (424) 94.0 97.1 (859) 7.20 2098-DSD-HV220
MPM-B2153F 3000 3800 43.86 45.6 (403) 94.0 94.8 (839) 7.20 2098-DSD-HV220
MPM-B2154B 1250 2000 35.46 62.7 (555) 94.0 149 (1319) 6.90 2098-DSD-HV220
MPM-B2154E 2250 3000 43.68 55.9 (495) 94.0 108 (956) 7.50 2098-DSD-HV220
MPM-B2154F 3000 3300 44.40 56.2 (497) 83.6 87.9 (778) 7.50 2098-DSD-HV220
Bulletin MPM Motor Performance Specifications with Ultra3000 (400V class) Drives (continued)
Rotary Motor
Speed,
base
rpm
Speed,
max
rpm
System Continuous
Stall Current
A 0-pk
System Continuous
Stall Torque
N•m (lb•in)
System Peak
Stall Current
A 0-pk
System Peak
Stall Torque
N•m (lb•in)
Motor Rated
Output
kW
Ultra3000
400V-class Drives
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2098-DSD-HV030 and MPM-B1151F
8.85
17.7
26.5
35.4
44.2
53.1
1.0
2.0
3.0
4.0
5.0
6.0
7.0
61.9
0
0
3000
5000
40001000
2000
0
Torque
(N•m)
Torque
(lb•in)
Speed (rpm)
2098-DSD-HV050 and MPM-B1151T
0
6000
80002000
4000
8.85
17.7
26.5
35.4
44.2
53.1
0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
61.9
0
= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage