Owner's manual

Publication 2098-RM001C-EN-P – August 2002
Programming Reference 2-87
324 Set Preset Position 5 DINT 4 Cnts If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0
325 Set Preset Position 5
Velocity
UDINT 4 Cnts /
Sec
The velocity used during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000
326 Set Preset Position 5
Accel
UDINT 4 Cnts /
Sec
2
The acceleration rate used to change to a higher
velocity during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000
327 Set Preset Position 5
Decel
UDINT 4 Cnts /
Sec
2
The deceleration rate used to change to a lower
velocity during a Preset Position 5 move.
Range: 0 to 0x7fffffff
Default: 100000
328 Set Preset Position 6 DINT 4 Cnts If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0
329 Set Preset Position 6
Velocity
UDINT 4 Cnts /
Sec
The velocity used during a Preset Position 6 move.
Range: 0 to 0x7fffffff
Default: 100000
330 Set Preset Position 6
Accel
UDINT 4 Cnts /
Sec
2
The acceleration rate used to change to a higher
velocity during a Preset Position 6 move.
Range: 0 to 0x7fffffff
Default: 100000
331 Set Preset Position 6
Decel
UDINT 4 Cnts /
Sec
2
The deceleration rate used to change to a lower
velocity during a Preset Position 6 move.
Range: 0 to 0x7fffffff
Default: 100000
332 Set Preset Position 7 DINT 4 Cnts If the drive is in Position Preset mode, then Preset
Select Lines 0, 1, and 2 select the Preset Position,
Preset Position Velocity, Preset Position Accel, and
Preset Position Decel parameters used during the
position move.
Range: -0x7fffffff to 0x7fffffff
Default: 0
333 Set Preset Position 7
Velocity
UDINT 4 Cnts /
Sec
The velocity used during a Preset Position 7 move.
Range: 0 to 0x7fffffff
Default: 100000
Parameter Object,
Instances ID = 1- 996
Parameter
Instance
Access
Rule
Parameter
Name
Data
Type
Data Size
(Bytes)
Units /
Scale
Description