Performance Specifications with Kinetix 300 (200V-class, three-phase) Drives (continued)
Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 40 °C (104 °F) ambient, and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software.
Kinetix 300 (200V-class) Drives/LDL-Series Linear Motor Curves
Linear Motor
Speed, max
m/s (ft/s)
System Continuous
Stall Current
Amps 0-pk
System Continuous
Stall Force
N (lb)
System Peak
Stall Current
Amps 0-pk
System Peak
Stall Force
N (lb)
Linear Motor
Rated Output
kW
Kinetix 300
200V-class
Three-phase Drives
LDL-N050480-DHT
10.0 (32.8)
10.9
383 (86)
36.3
1269 (285) 1.91
2097-V33PR6
LDL-N050480-EHT 5.5 18.1 2097-V33PR3
LDL-T050120-DHT 2.7 110 (25) 9.1 364 (82) 0.55 2097-V33PR1
LDL-T050240-DHT 5.5
220 (49)
18.1
728 (164) 1.10
2097-V33PR3
LDL-T050240-EHT 2.7 9.1 2097-V33PR1
LDL-T050360-DHT 8.2 329 (74) 27.2 1093 (246) 1.64 2097-V33PR5
LDL-T050480-DHT 10.9
439 (99)
36.3
1457 (327) 2.19
2097-V33PR6
LDL-T050480-EHT 5.5 18.1 2097-V33PR3
LDL-N075480-DHT 9.9
519 (117)
32.8
1723 (387) 2.59
2097-V33PR5
LDL-N075480-EHT 4.9 16.4 2097-V33PR3
LDL-T075480-DHT 9.9
596 (134)
32.8
1977 (444) 2.98
2097-V33PR5
LDL-T075480-EHT 4.9 16.4 2097-V33PR3
250
200
150
100
50
0
56.2
45.0
33.7
22.5
11.2
0
2097-V31PR2, 2097-V32PR2, or 2097-V33PR3
and LDL-N030120-DHT
Force
(N)
Force
(lb)
Velocity (m/s)
2
86
0
12
10
4
500
400
300
200
100
0
112
89.9
67.4
45.0
22.4
0
2097-V32PR4 or 2097-V33PR5 and LDL-N030240-DHT
2097-V31PR2, 2097-V32PR2, or 2097-V33PR3 and LDL-N030240-EHT
Force
(N)
Force
(lb)
Velocity (m/s)
2
86
0
12
10
4
= Intermittent operating region (LDL-xxxxxxx-DHT)
= Intermittent operating region (LDL-xxxxxxx-EHT)
= Continuous operating region