User Manual Owner manual
Publication 2093-UM001A-EN-P — January 2007
78 Connecting the Kinetix 2000 Drive System
VAC LINE (IPL) Connector (2094-AL09, 2094-ALxxS, and 2094-XL75S-Cx)
Wiring the VAC LOAD (OPL) Connector
Line Interface Module (OPL connector)
VAC LOAD (OPL) Connector (2094-ALxxS, or 2094-XL75S-Cx)
Three-phase Supply IPL Pin Signal
Recommended Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
Nm (lb-in.)
L1 4 L1
2.5...25 (14...4) 16.0 (0.63) 2.7 (24)
L2 3 L2
L3 2 L3
1
L3
L2
L1
1 2 3 4
Line Interface Module, Top View
(2094-XL75S-Cx is shown)
IMPORTANT
Line interface modules (2094-ALxxS, and 2094-XL75S-Cx) are capable
of connecting to two IAMs, providing each IAM has its own line filter
and the maximum current specification is not exceeded.
Refer to Power Wiring Examples on page 169 for an example of the
LIM wired to two IAMs.
Three-phase Supply OPL Pin Signal
Recommended Wire Size
mm
2
(AWG)
Strip Length
mm (in.)
Torque Value
Nm (lb-in.)
L1 4 L1’
2.5...25 (14...4) 16.0 (0.63) 2.7 (24)
L2 3 L2’
L3 2 L3’
1