User Manual Owner manual

Publication 2093-UM001A-EN-P — March 2007
Upgrading Firmware 191
12. Double-click on Parameter List to display the parameter functions.
Each parameter includes these functions.
For example, scrolling down to Parameter 30 (* 1:0.30 Version Data VER
01.95.18) indicates this is the IAM inverter, with version 01.95.18 (version
01.95, build 18). It is the first axis in the 2093 system or the IAM. To view
Column Description of Contents
S Status
R =
* =
Read only
Editable
N:P,P#
N =
P =
P# =
The node number of the device on the network
The port number (0 if a device)
The parameter number associated with a specific programming
parameter
Parameter number progression is:
0... 999 = Axis 1 (IAM)
1000...1999 = Axis 2
2000...2999 = Axis 3
3000...3999 = Axis 4
4000...4999 = Axis 5
5000...5999 = Axis 6
6000...6999 = Axis 7
7000...7999 = Axis 8
Name The item name
Value The present value of the item
Units The unit of measurement for the item