160 Specifications and Dimensions
Power Dissipation
Specifications
Use the following table to size an enclosure and calculate required ventilation
for your Kinetix 2000 system.
Kinetix 2000 Modules
Usage as a Percentage of Rated Power Output (Watts)
20% 40% 60% 80% 100%
Converter (IAM)
(1)
2093-AC05-MP1
Three-phase 7.0 10.5 14.0 17.4 20.9 2093-AC05-MP2
2093-AC09-MP5
2093-AC05-MP1
Single-phase 5.8 8.0 10.3 12.6 14.8 2093-AC05-MP2
2093-AC09-MP5
Inverter (IAM and AM)
(1)
2093-AC05-MP1 and 2093-AMP1 31.6 33.6 35.6 37.6 39.6
2093-AC05-MP2 and 2093-AMP2 33.0 36.4 39.8 43.3 46.8
2093-AC05-MP5 and 2093-AMP5 36.2 42.9 49.8 56.8 63.9
2093-AM01 38. 3 46.7 55. 3 64. 1 73. 1
2093-AM02 44. 3 55.6 67. 3 79.2 91.4
Shunt module (SM)
2093-ASP06 35.8 45.8 55.8 65.8 75.8
Power Rail
2093-PRSxx 0 0 0 0 0
Connector Kit
2093-K2CK-D15M 0 0 0 0 0
(1)
Internal shunt power is not included in the calculations and must be added based on utilization.