User Manual Owner manual
Publication 2093-UM001A-EN-P — March 2007
154 Specifications and Dimensions
Power Specifications
This section contains power specifications for your IAM or AM components.
Converter Power Specifications
The following tables list power specifications for the converter section that
resides within an integrated axis module.
IAM Converter (three-phase and single-phase) Power Specifications
Attribute
2093-AC05-MPx
Three-phase Input (230V nom)
2093-AC05-MPx
Single-phase Input (230V nom)
Input voltage, ac 170...264V rms
Input frequency, ac 47...63 Hz
Input current, ac main
(1)
Nom (rms)
Max inrush (0-pk)
11.66 A
34.0 A
10.95 A
34.0 A
Input voltage, dc (common bus follower) 240...375V dc
Input current, dc (common bus follower) 9.76 A 6.42 A
Control power ac input voltage 170...264V rms single-phase (230V nom)
Control power ac input current
Nom (@ 230V ac) rms
Max inrush (0-pk)
1.25 A
93.0 A
(2)
Bus output voltage, nom 325V dc
Line loss ride through 20 ms
Continuous output current to bus (A
dc
) 9.67 A 6.42 A
Intermittent output current to bus (A
dc
)
(3)
19.34 A 12.84 A
Bus overvoltage 425V dc
Bus undervoltage 137.5V dc
Internal shunt
Continuous power
Peak power
15 W
3000 W
Internal shunt resistor 50 Ω
Shunt on 405V
Shunt off 375V
Continuous power output to bus 3.0 kW 2.0 kW
Peak power output 6.0 kW 4.0 kW
Efficiency 95%
Converter inductance N/A
Converter capacitance 540 μF
Converter leakage current (max) 2.0 mA
(1)
All 2093-AC05 integrated axis modules are limited to two contactor cycles per minute (with up to four axis modules), or one contactor cycle per minute (with five to eight
axis modules).
(2)
Maximum inrush duration is less than 1/2 line cycle.
(3)
Intermittent output current duration equals 250 ms.