Design Guide User guide
Table Of Contents
- Front Cover - Kinetix 2000 Drive Systems Design Guide
- Introduction
- Determine What You Need
- Kinetix 2000 System Examples
- 2090-Series Motor/Actuator Cables Overview
- Kinetix 2000 Drives with MPL
- Kinetix 2000 Drives with MPM
- Kinetix 2000 Drives with MPF
- Kinetix 2000 Drives with MPS
- Kinetix 2000 Drives with TLY
- Bulletin TLY Motor Cable Combinations
- Bulletin TLY (non-brake) Motor Performance Specifications with Kinetix 2000 Drives
- Bulletin TLY (brake) Motor Performance Specifications with Kinetix 2000 Drives
- Kinetix 2000 Drives/TLY-AxxxP-B (absolute high-resolution) Motor Curves
- Kinetix 2000 Drives/TLY-AxxxT-H (incremental) Motor Curves
- Kinetix 2000 Drives/TLY-Axxxx-x Motor Curves
- Kinetix 2000 Drives with MPAS
- Kinetix 2000 Drives with MPAR
- Kinetix 2000 Drives with MPAI
- Kinetix 2000 Drives with TLAR
- Kinetix 2000 Drives with LDC-Series
- Kinetix 2000 Drives with LDL-Series
- Additional Resources
- Back Cover

40 Rockwell Automation Publication GMC-RM006A-EN-P - September 2011
Kinetix 2000 Drive Systems
Kinetix 2000 Drives/LDC-Series Linear Motor Curves (continued)
2093-AM02 and LDC-C100300-DHT
2093-AMP5 and LDC-C100300-EHT
Force
(N)
Force
(lb)
Velocity (m/s)
32
0
4
1
Water Cooling
2000
1750
1500
1250
1000
750
500
250
0
450
393
337
281
225
169
112
56.0
0
Air Cooling
No Cooling
2500
2000
1500
1000
500
0
562
450
337
225
112
0
2093-AM02 and LDC-C100400-DHT
2093-AM01 and LDC-C100400-EHT
Force
(N)
Force
(lb)
Velocity (m/s)
32
0
4
1
Water Cooling
Air Cooling
No Cooling
2093-AM02 and LDC-C100600-DHT
Force
(N)
Force
(lb)
Velocity (m/s)
32
0
4
1
Water Cooling
4000
3500
3000
2500
2000
1500
1000
500
0
899
787
674
562
450
337
225
112
0
Air Cooling
No Cooling
2093-AM02 and LDC-C150400-DHT
Force
(N)
Force
(lb)
4000
3500
3000
2500
2000
1500
1000
500
0
899
787
674
562
450
337
225
112
0
Velocity (m/s)
0.5
21.5
0
3
2.5
1
Water Cooling
Air Cooling
No Cooling
Velocity (m/s)
0.5
21.5
0
3
2.5
1
2093-AM02 and LDC-C150600-DHT
Force
(N)
Force
(lb)
Water Cooling
No Cooling
6000
5000
4000
3000
2000
1000
0
1349
1124
899
674
450
225
0
Air Cooling
= Intermittent operating region (LDC-Cxxxxxx-DHT)
= Intermittent operating region (LDC-Cxxxxxx-EHT)
= Continuous operating region