Rockwell Automation Publication 2080-UM005A-EN-E - December 2013 41
Communication Connections Chapter 5
EtherNet/IP to CIP Serial
Use Modems with
Micro800 Controllers
Serial modems can be used with the Micro820 controllers.
Making a DF1 Point-to-Point Connection
You can connect the Micro820 programmable controller to your serial modem.
The recommended protocol for this is Modbus RTU.
Construct Your Own Modem Cable
If you construct your own modem cable, the maximum cable length is 3 m (10 ft)
with a 25-pin or 9-pin connector. Refer to the following typical pinout for
constructing a straight-through cable:
EtherNet/IP
CIP Serial
Micro820
Controller
Micro820
Controller
46046
IMPORTANT
Micro800 controllers do not support more than one hop (for example,
from EtherNet/IP CIP Serial EtherNet/IP).
DTE Device
(Micro820
Channel 0)
DCE Device
(Modem, etc.)
niP-9niP-52niP-6
32DXTDXT5
23DXRDXR4
57DNGDNG6
18DCD)+(B1
402RTD)-(A2
66RSD3
85STC
74STR
DNG